6
. SPECIFICATIONS OF ELECTRICAL PARTS
6
-
1. Indoor Unit
6
-2. Outdoor Unit
No.
Fan motor (for indoor)
2 Room temp. sensor (TA-sensor)
10k
Ω
at 25°C
3 Heat exchanger temp. sensor (TC-sensor)
10k
Ω
at 25°C
4
5 Louver motor
Output (Rated) 1W, 16 poles, DC12V
( - )
(
-
)
MP24Z4N
MF-340-30-3
DC250~370
V
, 30W
Parts name
1
Specif ications
Type
Heat exchanger temp. sensor (T
CJ
-sensor)
10k
Ω
at 25°C
(
-
)
No.
Parts name
Model name
Rating
1
Reactor
CH-69-Z-T
L = 19mH, 10A
2
Outdoor fan motor
ICF-140-43-4R
DC140V, 43W
3
(Inverter attached)
10k
Ω
(25°C)
4
(Inverter attached)
62k
Ω
(20°C)
5
Suction temp. sensor (TS sensor)
Discharge temp. sensor (TD sensor)
Outside air temp. sensor (TO sensor)
(Inverter attached)
10k
Ω
(25°C)
6
Terminal block (5P)
JXO-5B
20A, AC250V
7
Compressor
(
1
0,13
k
)
DA108X1C-23FZ
3-phases 4-poles 750W
(18
k
)
DA131S1B-31FZ
3-phases 4-poles 1100W
8
Coil for PMV
CAM-MD12TCTH-5
DC12V
FILE NO. SVM-15058
- 19 -
Summary of Contents for RAS-18G2ACVP-T
Page 18: ...5 WIRING DIAGRAM FILE NO SVM 15058 18 ...