8
-2. Outdoor Unit (Inverter Assembly)
OUTDOOR UNIT
For INDOOR UNIT
220 V ~50Hz
MCC5009 (P.C.B)
MICRO-COMPUTER BLOCK DIAGRAM
Compressor
Outdoor
Fan motor
Current
detect
Current
detect
Gate drive
circuit
M.C.U.
•
PWM synthesis function
•
Input current release control
•
IGBT over-current detect control
•
Outdoor fan control
•
High power factor correction control
•
Inverter output frequency control
•
A/D converter function
•
PMV control
•
Discharge temp. control
•
Signal communication to indoor unit
Gate drive
circuit
Inverter
(DC
AC)
Inverter
(DC
AC)
Converter
(AC
DC)
PMV
: Pulse Motor Valve
M.C.U.
: Micro Control Unit
Clock
frequency
4MHz
Driver circuit
of PMV
PMV
High Power
factor Correction
circuit
Input current
sensor
Indoor unit
send/receive
circuit
Noise
Filter
Discharge
temp. sensor
Outdoor air
temp. sensor
Suction
temp. sensor
FILE NO. SVM-15058
- 24 -
Summary of Contents for RAS-18G2ACVP-T
Page 18: ...5 WIRING DIAGRAM FILE NO SVM 15058 18 ...