10-5-2. Power Supply and Connecting Cable Connection
Power Supply Input at Outdoor Unit Terminal Block (Optional)
Indoor Unit
Outdoor Unit
Connecting CABLE
Connecting cable connect to
terminal block (1, 2, 3,
˙
)
Stripping length of the connecting cable
3
Connecting cable
50 mm
10 mm
Earth line
about 20 cm
45 mm
10 mm
1
0
1
0
1
0
01
30
30
40
40
L N
1 2 3
Connecting cable
Earth line
Earth line
Connecting cable
Power cord
Power cord
Terminal block
1. The power supply must be same as the rated of air conditioner.
2. Prepare the power source for exclusive use with air conditioner.
3. Circuit breaker must be used for the power supply line of this air conditioner.
4. Be sure to comply power supply and connecting cable for size and wiring method.
5. Every wire must be connected fi rmly.
6. Perform wiring works so as to allow a general wiring capacity.
7. Wrong wiring connection may cause some electrical part burn out.
8. Incorrect or incomplete wiring is carried out, it will cause an ignition or smoke.
9. This product can be connected to main power supply.
Connection to fixed wiring : A switch which disconnects all poles and has a contact separation at least 3mm must be
incorporated in the fixed wiring.
CAUTION
FILE NO. SVM-15058
- 72 -