220–240V
~
50Hz
MICR
O-COMPUTER BLOCK DIA
GRAM
Driver circuit of P.M.V.
Heat exchanger temp.sensor
Suction temp.
sensor
Outdoor air temp. sensor
Discharge temp. sensor
Indoor unit send/receive
circuit
Drrive
circuit
Noise Filter
Converter (AC
→
DC)
Clock
frequency
10
MHz
High Power
factor Correction
circuit
High current
Detector
•
PWM synthesis function
•
Input current release control
•
I
PM
over-current detect control
•
Outdoor fan control
•
High power factor correction control
•
Inverter output frequency control
•
A/D converter function
•
P.M.V. control
•
Discharge temp. control
•
4-way valve control
•
Signal communication to indoor unit
P.M.V.
: Pulse Motor Valve
M.C.U. : Micro Control Unit
M.C.U
For INDOOR UNIT
4-way valve
P.M.V.
Inverter
(DC
→
AC)
Inverter
(DC
→
AC)
Outdoor Fan motor
Compressor
WP-03
0
(P
.C.B)
OUTDOOR UNIT
Current detect
Current detect
220
−
230V
~
60Hz
RAS-
1
6J2KVG-
E
E / RAS-
1
6J2AVG-
E
E
RAS-18J2KVG-
E
E / RAS-18J2AVG-E
E
FILE NO. SVM-19004