PRECAUTIONS FOR SAFETY

Read the precautions in this 

manual carefully before operating 

the unit.

This appliance is filled with R32.

● Keep this manual where the operator can easily find it.

● 

Read the precautions in this manual carefully before operating the unit.

● 

This appliance is intended to be used by expert or trained users in shops, in light

  industry and on farms, or for commercial use by lay persons.

● The precautions described herein are classified as DANGER, WARNING and

  CAUTION. They both contain important information regarding safety. Be sure to

  observe all precautions without fail.

 

DANGER

● Do not install, repair, open or remove the cover. It may expose you to

  dangerous voltages. Ask the dealer or the specialist to do this.

● Turning off the power supply will not prevent potential electric shock.

● The appliance shall be installed in accordance with national wiring regulation.

 Means for disconnection from the supply having a contact separation of at least

  3 mm in all poles must be incorporated in the fixed wiring.

● The appliance must be stored in a room without continuously operating ignition

  sources (for example, open flames, an operating gas appliance or an operating

  electric heater).

● In order to avoid fire, explosion or injury, do not operate the unit when harmful

  gases (e.g. flammable or corrosive) are detected near the unit.

 

WARNING

● Do not expose your body directly to cool or warm air for a long time.

● Do not insert your finger or any article into the air inlet/outlet.

● When an abnormality (burning smell, etc.) occurs, stop the air conditioner and

  disconnect the power supply or turn off the breaker.

● 

This appliance can be used by children aged from 8 years and above and

  persons with reduced physical, sensory or mental capabilities or lack of

  experience and knowledge if they have been given supervision or instruction

  concerning use of the appliance in a safe way and understand the hazards

  involved. Children shall not play with the appliance. Cleaning and user

  maintenance shall not be made by children without supervision.

● This appliance is not intended for use by person (including children) with

  reduced physical, sensory or mental capabilities, or lack of experience and

  knowledge, unless they have been given supervision or instruction concerning

  use of the appliance by a person responsible for their safety.

● 

The air conditioner must be installed, maintained, repaired and removed by a

  qualified installer or qualified service person. When any of these jobs is to be

  done, ask a qualified installer or qualified service person to do them for you.

● Children should be supervised to ensure that they do not play with the

 appliance.

● Do not use any refrigerant different from the one specified (R32) for 

  complement or replacement. Otherwise, abnormally high pressure may be 

  generated in the refrigeration cycle, which may result in a failure or explosion of  

  the product or an injury to your body.

1120650271-00_S01_182x257_16p_S_p70_190906_EN,TR.indd   2

23/12/2562   13:25:47

Summary of Contents for RAS-18J2AVSG-TR

Page 1: ...GLISH TÜRKÇE AIR CONDITIONER SPLIT TYPE For general public use Indoor unit RAS 18 22 24J2KVSG TR Outdoor unit RAS 18 22 24J2AVSG TR 1120650271 1120650271 00_S01_182x257_16p_S_p70_190906_EN TR indd 1 23 12 2562 13 25 47 ...

Page 2: ...arm air for a long time Do not insert your finger or any article into the air inlet outlet When an abnormality burning smell etc occurs stop the air conditioner and disconnect the power supply or turn off the breaker This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have be...

Page 3: ...use an electric shock Do not use this air conditioner for other purposes such as preserving food breeding animal etc Do not step or put anything on the indoor outdoor unit It may cause an injury or damage the unit Do not touch aluminium fin because it may cause an injury Before cleaning the unit turn off the main switch or the circuit breaker When the unit won t be used for a long time turn off th...

Page 4: ...elect AUTO LOW LOW MED MED HIGH or Quiet For dehumidification a moderate cooling performance is controlled automatically 1 Press Select Dry 2 Press Set the desired temperature Min 17 C Max 30 C Note DRY mode fan speed is set to Auto only To automatically control room temperature and airflow for faster cooling or heating operation except in DRY and FAN ONLY mode Press Start and stop the operation 1...

Page 5: ...tdoor unit Silent 2 Compromising the Heating or Cooling capacity to the Sound level in any circumstance where the outdoor unit s sound level is highly prioritized This setting has a purpose to reduce the maximum sound level of outdoor unit by 4 dB A Note While activating of Silent operation inadequate heating or cooling capacity may occur Power Selection and Silent Operation Outdoor Unit 100 SILEN...

Page 6: ...ioner will turn OFF The Remote Control B is memorized Picture 2 Note 1 Repeat above step to reset Remote Control to be A 2 Remote Control A has not A display 3 Default setting of Remote Control from factory is A 1 Three minute protection feature To prevent the unit from being activated for 3 minutes when suddenly restarted or switched to ON 2 Preheating operation Warm up the unit for 5 minutes bef...

Page 7: ...EEKLY TIMER OPERATION 24 EN Notes 1 Place the remote control where the indoor unit can receive the signal This will increase the accuracy of the timing between the remote control and the air conditioning unit 2 The ON OFF timer can be set during the WEEKLY TIMER operation In this situation the air conditioner will first follow the normal timer until it is complete then it will return to the WEEKLY...

Page 8: ... kaynaklarının örneğin açık alev çalışan gazlı bir cihaz veya çalışan bir elektrikli ısıtıcı gibi olmadığı bir odada muhafaza edilmelidir Yangın patlama ya da yaralanmayı önlemek için ünitenin yakınında zararlı gazlar örneğin çabuk ateş alan ya da aşındırıcı algılandığında üniteyi kullanmayın UYARI Uzun süre doğrudan soğuk havaya maruz kalmayIn Hava giriş çIkIşIna parmağInIzI veya herhangi bir nes...

Page 9: ...I bulunmadIğI bir odada muhafaza edilmelidir SoğutucularIn koku yaymadIğIndan emin olun Cihaz basInçlI olduğundan delmeyin veya yakmayIn CihazI IsI alev kIvIlcIm veya diğer kaynaklara veya tutuşmaya maruz bIrakmayIn Aksi takdirde patlayabilir ve yaralanma veya ölüme neden olabilir DİKKAT CihazI suyla yIkamayIn Elektrik çarpmasIna neden olabilir Bu klimayI yiyecek saklama ve koruma hayvan yetiştirm...

Page 10: ...Sessiz 1 tuşuna basın Soğuk Sıcak veya Sadece Fan modunu seçin 2 tuşuna basın İstediğiniz sıcaklığı ayarlayın Min 17 C Maks 30 C Fan Sıcaklık gösterilmiyor 3 tuşuna basın AUTO LOW LOW MED MED HIGH veya Sessiz Nem alma için yeterli soğutma performansı otomatik olarak kontrol edilir 1 tuşuna basın Kuru seçeneğini seçin 2 tuşuna basın İstediğiniz sıcaklığı ayarlayın Min 17 C Maks 30 C Not NEM ALMA mo...

Page 11: ...terli düzeyde konfor sağlanır Bu ayar Isıtma veya Soğutma kapasitesi ile dış ünitenin Ses düzeyi arasında kusursuz dengeyi sağlar Sessiz 2 Dış ünitenin ses düzeyinin öncelikli olduğu her durumda Ses düzeyindense Isıtma veya Soğutma kapasitesinden ödün verilir Bu ayar dış ünitenin maksimum ses düzeyini 4 dB A kadar azaltma amacı taşımaktadır Not Sessiz çalıştırma etkin olduğunda yetersiz ısıtma vey...

Page 12: ...ın ve hava giriş ızgarasını kapatın UZAKTAN KUMANDA A B SEÇİMİ 20 Yan yana iki iç ünitenin kurulu olduğu durumlarda uzaktan kumandanın üniteler üzerindeki kullanımını birbirinden ayırmak içindir Uzaktan Kumanda B AyarI 1 İç ünite üzerindeki RESET düğmesine basarak klima cihazını açın 2 Uzaktan kumandayı iç üniteye doğrultun 3 Uzaktan Kumandadaki düğmeyi kalemin ucu ile itin ve basılı tutun Ekranda...

Page 13: ...lenmesi gerekiyorsa lütfen ayar onayı öncesinde 2 8 arası adımları yineleyin 10 Ekleme veya düzenleme sonrasında ayarı doğrulamak için tuşuna basın Notlar 1 Uzaktan kumandayı iç ünitenin sinyali alabileceği bir yere yerleştirin Bu uzaktan kumanda ve klima ünitesi arasındaki zamanlama doğruluğunu artıracaktır 2 HAFTALIK ZAMANLAYICI işlevi sırasında AÇMA KAPAMA zamanlayıcısı ayarlanabilir Bu durumda...

Page 14: ...MEMO 1120650271 00_S01_182x257_16p_S_p70_190906_EN TR indd 14 23 12 2562 13 27 20 ...

Page 15: ...1120650271 00_S01_182x257_16p_S_p70_190906_EN TR indd 15 23 12 2562 13 27 20 ...

Page 16: ...ün tanıtım broşürlerine gerektiğinde Alarko Carrier Yetkili Satıcı ve Servislerine ulaşabilmek için 444 0 128 numaralı Müşteri Danışma Hattımıza başvurabilirsiniz 1120650271 1120650271 00_S01_182x257_16p_S_p70_190906_EN TR indd 16 23 12 2562 13 27 21 ...

Reviews: