FILE NO. SVM-06006
– 18 –
Standard 0.32 43.5 High 20/– 7/6
Heating High temperature*1 0.51 58.9 Low 27/– 24/18
Low temperature 0.18 38.4 High 20/–
–10/–10
Standard 0.43 11.0 High 27/19 35/24
Cooling High temperature 0.59 15.7 High 32/23 43/26
Low temperature 0.34 1.4 Low 21/15 21/15
5-3. RAS-24UFHP-E5 / RAS-24NAH-E
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
*1 : During heating overload, the high temperature limit control operation is included.
50Hz
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T (°C)
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
Evaporator
Indoor unit
Multi blade fan
Cooling
Heating
4-way valve
Heating Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
Capillary tube
∅
2.0x1400
S
PH400X3CS-4KT1
Accumulator
Cooling
Heating
Mark ( ) means check points of Gas Leak
O.D.:6.35 mm
Packed valve
0.49m
(Connecting pipe)
∅
6.35 mm
T
Capillary tube
∅
1.0x1200
S
Refrigerant
R-22 2.00kg
Packed valve
(
∅
15.88)
P
O.D.:15.88 mm
0.39m
(Connecting pipe)
∅
15.88 mm
∅
15.88 mm
0.39m
(Flexible pipe)
Cooling
Heating
(∅
6.35)