background image

1

Press 

FIX

 : Move the louver in the 

desired vertical direction.

2

Press 

SWING

 : Swing the air 

automatically and press again to stop.

3

For horizontal direction, adjust manually.

Preparing Filters

1.  Open the air inlet grille and remove the air fi lters.
2.  Attach the fi lters. (see detail in the accessory sheet).

Loading Batteries (when use wireless operation.)

1.  Remove the slide cover.
2.  Insert 2 new batteries (AAA type) 

following the (+) and (–) positions.

Clock Setup

1. Push 

 by tip of the pencil.

  If timer indication is fl ashing, go to the next step 2.

2. Press 

 or 

 : adjust the time.

3. Press 

 : Set the time.

Remote Control Reset

Push 

 by tip of the pencil or

1.  Remove the batteries.

2. Press 

.

3.  Insert the batteries.

Note:

 •  Do not move the louver manually by others.
 •  The louver may automation positioning by some operation mode.

Note:

 •  The provided Remote Controller is a wireless type, which also can be used as 
  a wire. Please see “How to Connect The Remote Controller for Wired 
  Operation”, located in installation instruction, in case of wired control is required.
 •  In wire operation, remote controller will return to initial condition (PRESET, 
  TIMER and CLOCK will return to initial condition) when user shutdown power 
  supply of Air conditioner.

1

   Infrared signal emitter

2

   Start/Stop button

3

   Mode select button (MODE)

4

   Temperature button (TEMP)

5

   Fan speed button (FAN)

6

   Swing louver button (SWING)

7

   Set louver button (FIX)

8

   On timer button (ON)

9

   Off timer button (OFF)

!

   Setup button (SET)

"

   Clear button (CLR)

#

   Memory and Preset button (PRESET)

$

  One-Touch button (ONE-TOUCH)

%

   High power button (Hi-POWER)

&

   Economy button (ECO)

(

   Quiet button (QUIET)

)

   Comfort sleep button (COMFORT SLEEP)

~

   Filter reset button (FILTER)

+

   Set clock button (CLOCK)

,

   Check button (CHECK)

-

   Reset button (RESET)

Press the “ONE-TOUCH” button for fully automated operation that is customized 
to the typical consumer preferences in your region of the world. The customized 
settings control temperature air fl ow strength, air fl ow direction and other settings 
to provide you alternate contact with “ONE-TOUCH” of the button. If you prefer 
other settings you can select from the many other operating functions of your 
Toshiba unit.

 Press 

ONE-TOUCH

 : Start the operation.

To automatically select cooling, heating or fan only operation

1.  Press 

MODE

 : Select A.

2.  Press 

 : Set the desired temperature.

3.   Press 

FAN

 : Select AUTO, LOW  , LOW+ 

, MED 

, MED+ 

, or 

HIGH 

.

1.  Press 

MODE

 : Select Cool 

, Heat 

, or Fan only 

.

2.  Press 

 : Set the desired temperature.

  Cooling: Min. 17°C, Heating: Max. 30°C, Fan Only: No temperature indication

3.  Press 

FAN

 : Select AUTO, LOW  , LOW+ 

, MED 

, MED+ 

or HIGH 

.

For dehumidifi cation, a moderate cooling performance is controlled automatically.

 1. 

Press 

MODE

 : Select Dry 

.

 2. 

Press 

 : Set the desired temperature.

To automatically control room temperature and airfl ow for faster cooling or heating 
operation (except in DRY and FAN ONLY mode)

Press 

Hi POWER

 : Start and stop the operation.

In case of the misplaced or discharged remote control

•  Pressing the RESET button, the unit can start or  
  stop without using the remote control.
•   Operation mode is set on AUTOMATIC 
  operation, preset temperature is 25°C 
  and fan operation is automatic speed.

Set the timer when the air conditioner is operating.

Setting the ON Timer

Setting the OFF Timer

Press 

 : Set the desired 

ON timer.

Press 

 : Set the desired OFF 

timer.

2

Press 

 : Set the timer. 

Press 

 : Set the timer.

3

Press 

 : Cancel the timer.

Press 

 : Cancel the timer.

Daily timer allows the user to set both the ON & OFF timers and will be 
activated on a daily basis.

Setting Daily Timer

1

Press 

 : Set the ON timer. 

3

Press 

.

2

Press 

 : Set the OFF timer.

4

Press 

 : button during the 

(  or  ) mark fl ashing.

•   During the every day timer is activating, both arrows ( ,  ) are indicated.

Note:

•   Keep the remote control in accessible transmission to the indoor unit; 

otherwise, the time lag of up to 15 minutes will occur.

•   The setting will be saved for the next same operation.

To automatically control room to save energy (except in DRY and FAN ONLY mode)

 

Press 

 : 

Start and stop the operation.

Note:

  Cooling operation; the set temperature will increase automatically 1 degree/    

hour for 2 hours (maximum 2 degrees increase). For heating operation the 
set temperature will decrease.

COOLING / HEATING / FAN ONLY OPERATION

7

DRY OPERATION

8

Hi-POWER OPERATION

9

ECO OPERATION

10

TEMPORARY OPERATION

11

TIMER OPERATION

12

PREPARATION BEFORE USE

2

AIR FLOW DIRECTION

3

REMOTE CONTROL

4

ONE-TOUCH

5

AUTOMATIC OPERATION

6

SWING

FAN

FIX

QUIET

Hi POWER

ONE-TOUCH

COMFORT

SLEEP

4

5

!
-

"

%

(

8

1

2

$

)
,

&

#

3

+

7

6

~

9

EN

ES

TSB_1110655124_(01_EN).indd   3

TSB_1110655124_(01_EN).indd   3

6/11/14   11:55 AM

6/11/14   11:55 AM

Summary of Contents for RAS-18N3AV Series

Page 1: ...al public use Indoor unit RAS 10 13 18 22 24N3KV Series Outdoor unit RAS 10 13 18 22 24N3AV Series OWNER S MANUAL 1110655124 ESPAÑOL FRANÇAIS ENGLISH TSB_1110655124_ cover indd 1 TSB_1110655124_ cover indd 1 6 9 14 4 20 PM 6 9 14 4 20 PM ...

Page 2: ...ycle which may result in a failure or explosion of the product or an injury to your body 1 Hi POWER Green 2 FILTER Orange 3 PRE DEF Preheat Defrost Orange 4 TIMER Yellow 5 OPERATION Green 6 RESET button 1 OPERATION Green 2 TIMER CLEANING Yellow 3 RESET button CAUTION Check that the circuit breaker is installed correctly If the circuit breaker is not properly installed it may cause an electric shoc...

Page 3: ...n To automatically select cooling heating or fan only operation 1 Press MODE Select A 2 Press Set the desired temperature 3 Press FAN Select AUTO LOW LOW MED MED or HIGH 1 Press MODE Select Cool Heat or Fan only 2 Press Set the desired temperature Cooling Min 17 C Heating Max 30 C Fan Only No temperature indication 3 Press FAN Select AUTO LOW LOW MED MED or HIGH For dehumidification a moderate coo...

Page 4: ...use another recommended heating apparatus in combination with the air conditioner 6 Consideration for accumulated snow Select the position for outdoor unit where it will not be subjected to snow drifts accumulation of leaves or other seasonal debris 7 Some minor cracking sound may occur when unit operating This is normal because the cracking sound may be caused by expansion contraction of plastic ...

Page 5: ...綠色 FILTER 篩檢程式燈 橙色 PRE DEF 化霜預熱 橙色 TIMER 黃色 OPERATION 操作燈 綠色 RESET 重設 鍵 注意 檢查電路斷路器是否已安裝穩妥 如果電路斷路器沒有正確安裝 可能導致觸 電 要檢查安裝方法 請聯絡零售商或安裝本機的專業經銷商 在封閉空間內使用本機時 或在使用脈衝燃燒設備時操作本機 務必不時打開窗 口進行通風 通風不足可能導致因缺氧而窒息 避免在高濕度 超過 80 環境中 例如門窗開啟時 長時間操作本機 室內 機組上可能會發生冷凝 水滴可能會跌落到傢俱上 如果長時間不使用本機 請關閉主電源開關或電路斷路器 如果長時間操作本機 建議由專業技術人員來執行維修工作 每年至少進行一次檢查 以確保室外機組的安裝台沒有損壞 如果忽略了損壞情 況 本機可能會跌落或翻轉 導致受傷 安裝 拆下前面板 空氣過濾器 空氣清洗過濾器時請站立在穩固的梯子上 否則可 能...

Page 6: ...將遙控器保持在可傳送至室內機的接收範圍內 否則 將出現達 15 分鐘的 時滯 設定將被儲存 方便您下一次進行同樣的操作 定時操作 12 安裝過濾器 1 打開空氣進口格柵 並取出空氣過濾器 2 安裝器 參考附表來瞭解細節 安裝電池 使用無線操作時 1 打開電池蓋 2 按照 和 極裝入兩節新的 AAA 型 電池 時鐘設置 1 通過筆尖推動 如果定時器指示閃爍 請轉到下個步驟 2 2 按 或 調整時間 3 按 設定時間 遙控器重設 或用筆尖推動 1 卸下電池 2 按 3 安裝電池 使用前的準備工作 2 1 按 FIX 移動百葉片於所要的垂 直方向 2 按 SWING 自動搖擺氣流 再按一 次以停止 3 至於水平方向 則請手動調整 注 不要讓他人用手移動百葉片 通過開始操作模式可以自動設定百葉片的位置 風向 3 紅外線信號發射器 啟動 停止鍵 模式選擇鍵 MODE 溫度鍵 TEMP 風扇速度鍵 F...

Page 7: ...定日後使用的首選操作 本機將儲存設定以方便您日後操作 氣流方向除外 1 選擇您的首選操作 2 按住 鐘 3 秒鐘已儲存設定 標誌將顯示 3 按 進行預設操作 預設操作 13 電流中斷後自動重新啟動空調器 本機的電源必須已打開 設定 1 按住室內機組上的 RESET 按鈕 3 秒鐘來設定操作 3 聲嗶聲且 OPERATION 燈閃爍 5 秒鐘 1 秒閃爍 5 次 2 按住室內機組上的 RESET 按鈕 3 秒鐘來取消操作 3 聲嗶聲 但 OPERATION 燈不閃爍 在設定了開機定時器或關機定時器的情況下 自動重啟操作不會啟動 自動重新啟動操作 14 在超低風扇速度下進行靜音運行 除濕 DRY 模式中除外 按 QUIET 啟動和停止操作 注 在某些條件下 由於低聲響特性 QUIET 靜音 操作可能無法提供足夠 的製冷效果 靜音模式 15 在睡眠時為了節省能量 自動控制氣流並自動 OFF 關閉...

Page 8: ...DI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND Name of the Importer Distributor in EU TOSHIBA CARRIER UK LTD Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 1110655124 TSB_1110655124_ cover indd 2 TSB_1110655124_ cover indd 2 6 9 14 4 20 PM 6 9 14 4 20 PM ...