background image

Set your preferred operation for future use. The setting will be memorized by the 
unit for future operation (except airfl ow direction).
  1.  Select your preferred operation.

 2. 

 

Press and hold 

 for 3 seconds to memorize the setting. 

The 

P

 mark displays.

 3. 

Press 

 : Operate the preset operation.

To automatically restart the air conditioner after the power failure (Power of the 
unit must be on.)

Setting

1.  Press and hold the RESET button on the indoor unit for 3 seconds to set 

the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 
5 seconds)

2.  Press and hold the RESET button on the indoor unit for 3 seconds to cancel 

the operation. (3 beep sound but OPERATION lamp does not blink)

 

•  In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
  does not activate.

To operate at super low fan speed for quiet operation (except in DRY mode)

 Press 

QUIET

 : Start and stop the operation.

 Note: 

Under certain conditions, QUIET operation may not provide adequate  

  cooling due to low sound features.

For comfortable sleep, automatically control air fl ow and automatically turn OFF.

 Press 

 : Select 1, 3, 5 or 9 hrs for OFF timer operation.

 Note: 

The cooling operation, the set temperature will increase automatically 

  1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
     operation, the set temperature will decrease.

 Firstly, turn off the circuit breaker.

Filter Reset (Some models only)

FILTER lamp lights on; the fi lter must be cleaned.
To turn off the lamp, push the RESET button on the indoor unit or the FILTER
button on the remote control.

Indoor Unit and Remote Control

•   Clean the indoor unit and the remote control with a wet cloth when needed. 
•   No benzine, thinner, polishing powder or chemically-treated duster.

 

1.   Three-minute protection feature: To prevent the unit from being activated   
 

for 3 minutes when suddenly restarted or switched to ON.

 

2.  Preheating operation: Warm up the unit for 5 minutes before blowing warm air.

 

3.  Warm air control: When the room temperature reaches the set temperature, 
 

the fan speed is automatically reduced and the outdoor unit will stop.

 

4.  Automatic defrosting: Fans will stop during defrost operation.

 

5.  Heating capacity: Heat is absorbed from outdoor and released into the room.
 

When the outdoor temperature is too low, use another recommended heating

 

apparatus in combination with the air conditioner.

 

6.  Consideration for accumulated snow: Select the position for outdoor unit where
 

it will not be subjected to snow drifts, accumulation of leaves or other seasonal

 debris.

 

7.  Some minor cracking sound may occur when unit operating. This is normal
 

because the cracking sound may be caused by expansion/contraction of

 plastic.

 

Note:

 Item 2 to 6 for Heating model

Air conditioner operating conditions

To protect bad smell caused by the humidity in the indoor unit.

1. If the 

 button is pressed once during “Cool” or “Dry” mode, 

 

the fan will continue to run for other 30 minutes, then it will turn off 
automatically. This will reduce the moisture in the indoor unit.

2.  To stop the unit immediately, press the 

 more 2 times within 

30 seconds.

Temp. 

Operation

Outdoor Temperature

Room

Temperature

13, 18, 22, 24N3KV 

Series

10N3KV Series

Heating

–15°C ~ 24°C

–10°C ~ 24°C

Less than 28°C

Cooling

–10°C ~ 46°C

15°C ~ 43°C

21°C ~ 32°C

Dry

–10°C ~ 46°C

15°C ~ 43°C

17°C ~ 32°C

To separate using of remote control for each indoor unit in case of 2 air 
conditioners are installed nearly.

Remote Control B Setup.

1.  Press RESET button on the indoor unit to turn the air conditioner ON. 
2.  Point the remote control at the indoor unit.
3.  Push and hold 

 button on the Remote Control by the tip of the pencil.

   “00” will be shown on the display.

4.  Press 

 during pushing 

. “B” will show on the display and “00” 

will disappear and the air conditioner will turn OFF. The Remote Control B 
is memorized.

Note: 

1.  Repeat above step to reset Remote Control to be A.

   

2.  Remote Control A has not “A” display.

   

3.  Default setting of Remote Control from 

factory is A.

The unit does not operate.

Cooling or Heating is abnormally low.

•   The power main switch is turned 

off. 

•   The circuit breaker is activated to 

cut off the power supply. 

•   Stoppage of electric current. 
•   ON timer is set. 

•   The fi lters are blocked with dust.
•   The temperature has been set 

improperly.

•   The windows or doors are opened.
•   The air inlet or outlet of the outdoor 

unit is blocked.

•   The fan speed is too low.
•   The operation mode is FAN or DRY.

OPERATION AND PERFORMANCE

19

TROUBLESHOOTING (CHECK POINT)

20

REMOTE CONTROL A-B SELECTION

21

PRESET OPERATION

13

AUTO RESTART OPERATION

14

QUIET OPERATION

15

COMFORT SLEEP OPERATION

16

MAINTENANCE

17

SELF CLEANING OPERATION (COOL AND  

 

DRY OPERATION ONLY)

18

TSB_1110655124_(01_EN).indd   4

TSB_1110655124_(01_EN).indd   4

6/11/14   11:55 AM

6/11/14   11:55 AM

Summary of Contents for RAS-18N3AV Series

Page 1: ...al public use Indoor unit RAS 10 13 18 22 24N3KV Series Outdoor unit RAS 10 13 18 22 24N3AV Series OWNER S MANUAL 1110655124 ESPAÑOL FRANÇAIS ENGLISH TSB_1110655124_ cover indd 1 TSB_1110655124_ cover indd 1 6 9 14 4 20 PM 6 9 14 4 20 PM ...

Page 2: ...ycle which may result in a failure or explosion of the product or an injury to your body 1 Hi POWER Green 2 FILTER Orange 3 PRE DEF Preheat Defrost Orange 4 TIMER Yellow 5 OPERATION Green 6 RESET button 1 OPERATION Green 2 TIMER CLEANING Yellow 3 RESET button CAUTION Check that the circuit breaker is installed correctly If the circuit breaker is not properly installed it may cause an electric shoc...

Page 3: ...n To automatically select cooling heating or fan only operation 1 Press MODE Select A 2 Press Set the desired temperature 3 Press FAN Select AUTO LOW LOW MED MED or HIGH 1 Press MODE Select Cool Heat or Fan only 2 Press Set the desired temperature Cooling Min 17 C Heating Max 30 C Fan Only No temperature indication 3 Press FAN Select AUTO LOW LOW MED MED or HIGH For dehumidification a moderate coo...

Page 4: ...use another recommended heating apparatus in combination with the air conditioner 6 Consideration for accumulated snow Select the position for outdoor unit where it will not be subjected to snow drifts accumulation of leaves or other seasonal debris 7 Some minor cracking sound may occur when unit operating This is normal because the cracking sound may be caused by expansion contraction of plastic ...

Page 5: ...綠色 FILTER 篩檢程式燈 橙色 PRE DEF 化霜預熱 橙色 TIMER 黃色 OPERATION 操作燈 綠色 RESET 重設 鍵 注意 檢查電路斷路器是否已安裝穩妥 如果電路斷路器沒有正確安裝 可能導致觸 電 要檢查安裝方法 請聯絡零售商或安裝本機的專業經銷商 在封閉空間內使用本機時 或在使用脈衝燃燒設備時操作本機 務必不時打開窗 口進行通風 通風不足可能導致因缺氧而窒息 避免在高濕度 超過 80 環境中 例如門窗開啟時 長時間操作本機 室內 機組上可能會發生冷凝 水滴可能會跌落到傢俱上 如果長時間不使用本機 請關閉主電源開關或電路斷路器 如果長時間操作本機 建議由專業技術人員來執行維修工作 每年至少進行一次檢查 以確保室外機組的安裝台沒有損壞 如果忽略了損壞情 況 本機可能會跌落或翻轉 導致受傷 安裝 拆下前面板 空氣過濾器 空氣清洗過濾器時請站立在穩固的梯子上 否則可 能...

Page 6: ...將遙控器保持在可傳送至室內機的接收範圍內 否則 將出現達 15 分鐘的 時滯 設定將被儲存 方便您下一次進行同樣的操作 定時操作 12 安裝過濾器 1 打開空氣進口格柵 並取出空氣過濾器 2 安裝器 參考附表來瞭解細節 安裝電池 使用無線操作時 1 打開電池蓋 2 按照 和 極裝入兩節新的 AAA 型 電池 時鐘設置 1 通過筆尖推動 如果定時器指示閃爍 請轉到下個步驟 2 2 按 或 調整時間 3 按 設定時間 遙控器重設 或用筆尖推動 1 卸下電池 2 按 3 安裝電池 使用前的準備工作 2 1 按 FIX 移動百葉片於所要的垂 直方向 2 按 SWING 自動搖擺氣流 再按一 次以停止 3 至於水平方向 則請手動調整 注 不要讓他人用手移動百葉片 通過開始操作模式可以自動設定百葉片的位置 風向 3 紅外線信號發射器 啟動 停止鍵 模式選擇鍵 MODE 溫度鍵 TEMP 風扇速度鍵 F...

Page 7: ...定日後使用的首選操作 本機將儲存設定以方便您日後操作 氣流方向除外 1 選擇您的首選操作 2 按住 鐘 3 秒鐘已儲存設定 標誌將顯示 3 按 進行預設操作 預設操作 13 電流中斷後自動重新啟動空調器 本機的電源必須已打開 設定 1 按住室內機組上的 RESET 按鈕 3 秒鐘來設定操作 3 聲嗶聲且 OPERATION 燈閃爍 5 秒鐘 1 秒閃爍 5 次 2 按住室內機組上的 RESET 按鈕 3 秒鐘來取消操作 3 聲嗶聲 但 OPERATION 燈不閃爍 在設定了開機定時器或關機定時器的情況下 自動重啟操作不會啟動 自動重新啟動操作 14 在超低風扇速度下進行靜音運行 除濕 DRY 模式中除外 按 QUIET 啟動和停止操作 注 在某些條件下 由於低聲響特性 QUIET 靜音 操作可能無法提供足夠 的製冷效果 靜音模式 15 在睡眠時為了節省能量 自動控制氣流並自動 OFF 關閉...

Page 8: ...DI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND Name of the Importer Distributor in EU TOSHIBA CARRIER UK LTD Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 1110655124 TSB_1110655124_ cover indd 2 TSB_1110655124_ cover indd 2 6 9 14 4 20 PM 6 9 14 4 20 PM ...

Reviews: