Initial setting of “Cooling storage position”
Louver : Horizontal blowing (37.4°)
Initial setting of “Heating storage position”
Louver : Directs downward (76.9°)
Heating operation/
AUTO (HEAT)
Cooling operation/
AUTO (COOL)
Air direction
Inclined
blowing
Blowing
downward
Inclined
blowing
Horizontal
blowing
Horizontal
blowing
Item
8. Louver control
1) Louver
position
2) Air direction adjustment
3) Swing
Operation flow and applicable data, etc.
This function controls the air direction of the indoor unit.
• The position is automatically controlled according to the operation
mode (COOL/HEAT).
• The set louver position is stored in memory by the microcomputer,
and the louver returns to the stored position when the next operation
is performed. (Cooling/heating memory position)
The angle of the louver is indicated as the horizontal angle is 0°.
1) Louver position in cooling operation
2) Louver position in heating operation
• Swing operation is performed in width 35° with the stop position as
the center.
• If the stop position exceeds either upper or lower limit position, swing
operation is performed in width 35° from the limit which the stop
position exceeded.
Description
• The louver position can
be arbitrarily set up by
pushing [FIX] button.
• Swing
When pushing [SWING]
button during operation,
the louver starts
swinging.
FILE NO. SVM-12056
–
35
–