L N
1 2 3
Connecting cable
Power cord
Connecting cable
Power cord
Terminal
block
Earth line
•
Wrong wiring connection may cause some electrical
parts burn out.
•
Be sure to comply with local cords on running the
wire from indoor unit to outdoor unit (size of wire
and wiring method, etc.).
•
Every wire must be connected firmly.
•
This installation circuit breaker must be used specified
Fig. 10-4-9
<Stripping length of the connecting cable>
CAUTION
for the power supply line of this air conditioner.
•
If incorrect or incomplete wiring is carried out, it will
cause an ignition or smoke.
•
Prepare the power supply for exclusive use with the
air conditioner.
•
This product can be connected to the mains.
Connection to fixed wiring: A switch which
disconnects all poles and has a contact separation
of at least 3 mm must be incorporated in the fixed wiring
10-5. Others
•
Check the flare nut connections for the gas leak with
a gas leak detector or soap water.
F ig. 10-5-1
10-5-1. Gas leak test
10-5-2. Remote Control A-B Selection
•
When two indoor units are installed in the same room or
adjacent two rooms, if operating a unit, two units may
receive the remote control signa
l
simultaneously and
operate. In this case, the operation can be preserved
by setting either one remote control to B setting.
(Both are set to A setting in factory shipment.)
•
The remote control signal is not received when the
settings of indoor unit and remote control are different.
•
There is no relation between A setting/B setting and A
room/B room when connecting the piping and cables.
<Remote control A-B selection>
To separate using of remote control for each indoor unit
in case of 2 air conditioners are installed nearly.
<Remote Control B Setup>
1. Press [RESET] button on the indoor unit to turn the air
conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHECK] button on the Remote Control
by the tip of the pencil. "00" will be shown on the display
4. Press [MODE] during pushing [CHECK]. "B" will show
on the display and "00" will disappear and the air
conditioner will turn OFF. The Remote Control B
is memorized (Picture ).
(Picture ).
1
2
Check places
for outdoor unit
Electric parts
cover
Check places for
indoor unit (Flarenut
connection)
Power source
Model
Maximum running current
Plug socket & fuse rating
18 Class
Connecting cable
220V Single phase, 60Hz
Power cord
10.0
A
2
2
Class
13.5
A
16
A
16
A
H07RN-F or 60245 IEC66
(1.5 mm
2
)
H07RN-F or 60245 IEC66
(1.0 mm
2
)
220 - 240V Single phase, 50Hz
–
62
–