background image

27

EN

Before asking for servicing or repairs, check the following points.

TROUBLESHOOTING (Remote Controller)

The remote controller does not operate correctly.

Symptoms

Causes

Possible Solution

The operating mode switches.

• Check whether the MODE indicated 

on the display is AUTO.

The fan speed and louver direction 
cannot be changed in AUTO mode.
When the SWING, FIX or FAN buttons 
are pressed in AUTO mode, the mode 
changes to A mode.

The fan speed cannot be 
changed.

• Check whether the MODE indicated 

on the display is 

: DRY.

When dry operation is selected, the air 
conditioner automatically selects the 
fan speed. The fan speed can be 
selected during 

 COOL and 

HEAT.

The Display Goes Off

Symptoms

Causes

Description

The indicators on the display 
are not shown after a short 
time.

• Check whether the timer operation is 

over when the OFF TIMER is shown 
on the display.

The air conditioner stops since the 
setting time has elapsed.

The TIMER display turns off 
after a certain period of time.

• Check whether the timer operation 

has started when the ON TIMER is 
shown on the display.

When the time reaches the time 
setting for the ON timer operation, the 
air conditioner starts to operate 
automatically and the ON timer display 
turns off.

The Signal Receiving Tone Does Not Sound

Symptoms

Causes

Description

No receiving tone is made from 
the indoor unit even when the 

 button is pushed.

• Check whether the infrared signal 

transmitter of the remote controller is 
properly pointed towards the receiver 
of the indoor unit when the 

 button 

is pushed.

Point the infrared signal transmitter of 
the remote controller towards the 
receiver of the indoor unit, and then 
press the 

 button repeatedly.

AUTO

: DRY

: ON

Summary of Contents for RAS-18PAVP-E

Page 1: ...nit Outdoor Unit RAS 07PKVP E RAS 10PKVP E RAS 13PKVP E RAS 16PKVP E RAS 18PKVP E RAS 07PKVP ND RAS 10PKVP ND RAS 13PKVP ND RAS 16PKVP ND RAS 18PKVP ND RAS 07PAVP E RAS 10PAVP E RAS 13PAVP E RAS 16PAVP E RAS 18PAVP E RAS 07PAVP ND RAS 10PAVP ND RAS 13PAVP ND RAS 16PAVP ND RAS 18PAVP ND ...

Page 2: ...N 11 DRY OPERATION 11 8 C OPERATION RAS ND model only 12 PURE OPERATION 13 Hi POWER OPERATION 13 TIMER OPERATION 14 MEMORY MY COMFORT OPERATION 16 ADJUSTING AIR FLOW DIRECTION 17 AUTO RESTART OPERATION 18 HOW THE AIR CONDITIONER WORKS 19 TEMPORARY OPERATION 20 CLEANING OPERATION 20 USUAL MAINTENANCE 21 AIR CONDITIONER OPERATION AND PERFORMANCE 23 TROUBLESHOOTING 24 TROUBLESHOOTING Remote Controlle...

Page 3: ...y damage 3 Never do Beware of rotating parts Electrical hazard Contact with water will cause electric shock Do NOT touch with wet hands Always unplug when not in use Risk of finger injury Always follow the instructions Do not get the product wet DANGER Do not install repair open or remove the cover It may expose you to dangerous voltages Ask the dealership or the specialist to do this Turning off ...

Page 4: ...ric shock Please contact the supplying retail dealership for repair Do not clean the inside of the air conditioning unit yourself Please request internal cleaning of the air conditioning unit from the supplying retail dealership Incorrect cleaning may cause breakage of resin parts or insulation defects of electrical parts causing water leakage electric shock or fire Do not damage or modify the pow...

Page 5: ...lay plants precision devices or art objects Do not use on ships or in other vehicles It may cause a failure in the air conditioning unit In addition it may damage these items Do not place other electrical appliances or furniture under the unit Water droplets might fall causing damage or failure When performing maintenance you must stop operating the unit and turn off the circuit breaker Since the ...

Page 6: ...1 If the orange light of the PURE indicator is turned on this indicates a problem in the plasma ion charger Please contact the dealer where you made the purchase RESET button The RESET button has the following function Temporary operation function Use when you misplace or lose the remote controller or when its batteries are used up see page 20 NAMES OF PARTS CAUTION RAS ND model only Use care to a...

Page 7: ...on OFF Use this button to change the OFF timer times To move up the time press of the OFF button To move down the time press of the OFF button j Reserve button SET Press this button to store the time settings A receiving beep is heard k Cancel button CLR Press this button to cancel the ON timer and OFF timer A receiving beep is heard l High power button Hi POWER Press this button to start high pow...

Page 8: ...r 3 seconds when the MEMO button is pressed during operation The mark is shown when holding down the button for 3 seconds or more while the mark is flashing Press another button to turn off the mark i SLEEP MODE indicator Indicates when the SLEEP MODE is activated Press the SLEEP MODE button to start and press it again to stop operation j A B change indicator remote controller When the remote cont...

Page 9: ... while pressing the sides Battery replacement Be careful not to reverse the position and the position Setting the clock Before you start operating the air conditioner set the clock of the remote controller using the procedures given in this section The clock panel on the remote controller will indicate the time regardless of whether the air conditioner is in use or not Initial setting When batteri...

Page 10: ... button or OFF button to set the current time Each press of the ON button or OFF button changes the time in one minute increments Holding down the ON button or OFF button changes the time in ten minute increments c SET button Press the SET button The current time is displayed and the clock starts a b c Push CLOCK ON OFF ON OFF SET SET ...

Page 11: ...nged beep Stop Beep beep Notify When the notification sound beep beep is made This indicates that the temperature fan speed or air flow direction settings were returned to the basic settings USING THE REMOTE CONTROLLER CAUTION The air conditioner will not operate if curtains doors or other objects block the signals from the remote controller to the indoor unit Be careful that liquids do not spill ...

Page 12: ...The fan speed indicator is also shown Stop button Press this button again to stop the air conditioner When you set the air conditioner to A mode or switch over from AUTO operation because of a change in settings the air conditioner automatically selects cooling or heating operation depending on the room temperature see page 19 Start a button Press this button to start the air conditioner b Mode se...

Page 13: ...inutes Stop button Press this button again to stop the air conditioner Start a button Press this button to start the air conditioner b Mode select button MODE Select DRY c Temperature button Set the desired temperature The fan speed setting is fixed to AUTO and the AUTO is displayed The OPERATION indicator green on the display panel of the indoor unit turns on and operation starts after approximat...

Page 14: ...ately 3 minutes If the air conditioner performs a heating operation it changes immediately to the 8 C heating operation If the air conditioner performs a PURE operation it performs both the pure operation and 8 C heating Stop button Press this button to stop the air conditioner If the 8 C heating operation starts while the air conditioner is operating press the 8 C button again to return to the pr...

Page 15: ...e indoor unit turns on INFORMATION INFORMATION During PURE operation a small amount of ozone is produced and you might notice the smell When the fan speed is automatic it changes up to MED During Hi POWER operation the position of the vertical air flow louver changes to the high power position High power Hi POWER The Hi POWER high power operation mode automatically controls room temperature air fl...

Page 16: ...s displayed and the timer starts c CLR button Press the CLR button to cancel the timer setting Once you select timer operation mode the settings are saved in the remote controller Thereafter the air conditioner will start operating under the same conditions as you adjusted by the or button on the remote controller You cannot set the timer when the clock display is flashing Follow the instructions ...

Page 17: ...F timers no timer operation is performed Also the air conditioner may stop operating Daily combined timer setting the ON and OFF timers simultaneously and activating every day This feature is useful when you want to use the combined timers at the same time every day Setting combined TIMER 1 Press the ON button to set the ON timer 2 Press the OFF button to set the OFF timer 3 Press the SET button 4...

Page 18: ...nds or if you press another button the MEMORY setting is cancelled Operation modes which can be stored with the MEMO button are MODE Temperature FAN TIMER and Hi POWER To operate the air conditioner with the setting stored using the MEMO button a MY COMFORT button Press the MY COMFORT button The setting stored with the MEMO button will be shown and the air conditioner operates based on the setting...

Page 19: ...izontal air flow louver swings The vertical air flow louver and horizontal air flow louver swing at the same time The swinging of the vertical air flow louver and horizontal air flow louver is stopped Press FIX to change the center position of the vertical air flow louver swinging Press FIX to change the center position of the horizontal air flow louver swinging To stop the function press the SWIN...

Page 20: ...t accept a command if timer operation with the remote controller is activated After restarting the air conditioner by the AUTO RESTART OPERATION the louver swing AUTO operation resumes To cancel the auto restart operation proceed as follows Repeat the setting procedure The air conditioner receives the setting and beeps 3 times Now the auto restart setting is cancelled The air conditioner needs to ...

Page 21: ...ortable room in winter Dry operation The dry mode automatically selects the cooling dry operation based on the difference between the temperature setting and the actual room temperature The fan speed indicator shows AUTO and low speed is used The display panel indicators will decrease in brightness in sleep mode HOW THE AIR CONDITIONER WORKS INFORMATION INFORMATION The power and noise level are re...

Page 22: ...tioner When the unit shuts down after having operated for 10 or more minutes in the cooling or dry mode the cleaning operation is started automatically and the S CLEAN indicator on the unit s display panel turns on Cleaning operation duration The cleaning operation lasts for 4 hours if the unit has been operating in the cooling or dry mode for 10 minutes or more About the cleaning operation The cl...

Page 23: ...WARNING Before you clean the air conditioner be sure to turn off the circuit breaker or main power switch CAUTION Use a dry cloth to wipe the indoor unit and remote controller When the air conditioner is extremely dirty use a cloth dipped in cold water to wipe the indoor unit Never use a damp cloth on the remote controller Do not use a chemical based duster for wiping or leave such materials on th...

Page 24: ...t out to the front 5 Use a vacuum cleaner to remove the dust from the filters or wash them with water After washing the air filters dry them in the shade 6 Insert the top section of the air filter so that its right and left edges fit on the indoor unit 7 Close the moving panel Grasp the moving panel with your left hand and use your right hand to lower the panel support downward and push on the two...

Page 25: ... at sub zero temperatures the water drained off the outdoor unit as a result of the automatic defrost may accumulate and freeze It is important that adequate drainage or a soak way be provided Power failure Power failure during operation stops the unit completely The OPERATION indicator green on the indoor unit starts flashing when power is restored To restart operation push the button on the remo...

Page 26: ...ectric current has stopped The batteries in the remote controller used up The ON timer is set As a protective mechanism for the air conditioner it does not operate for 3 minutes immediately after restarting operation or turning on the main power Poor cooling or heating performance The air inlet or outlet of the outdoor unit is blocked Doors or windows are opened The air filter is clogged with dust...

Page 27: ...st sometimes forms on the outdoor unit during heating operation In that case the unit automatically performs defrosting for 2 to 10 minutes for improving the heating efficiency In the defrosting operation the airflow from both the indoor and outdoor units stops A hiss sound is heard when the flow of the refrigerant is changed for defrosting The water resulting from automatic defrosting during the ...

Page 28: ... is stopped the vertical air flow louvers may make a rattling sound or shuttling sound Some parts may expand or shrink due to temperature fluctuations and this can result in a slapping sound When the refrigerant is flowing a hissing sound or gurgling sound can result A hissing sound can be made when the air conditioner is switched to defrosting operation during heating operation An operation sound...

Page 29: ...e not shown after a short time Check whether the timer operation is over when the OFF TIMER is shown on the display The air conditioner stops since the setting time has elapsed The TIMER display turns off after a certain period of time Check whether the timer operation has started when the ON TIMER is shown on the display When the time reaches the time setting for the ON timer operation the air co...

Page 30: ...r Unit Indoor Unit Outdoor Unit RAS 13PKVP E RAS 13PKVP ND RAS 13PAVP E RAS 13PAVP ND RAS 16PKVP E RAS 16PKVP ND RAS 16PAVP E RAS 16PAVP ND Power supply 220 240 V 50 Hz 220 230 V 60 Hz 220 240 V 50 Hz 220 230 V 60 Hz Cooling capacity kW CAPA 3 5 4 5 Heating capacity kW CAPA 4 0 5 5 Cooling current A AMP 0 24 0 22 3 44 3 15 0 27 0 25 5 54 5 08 Cooling power W WATT 30 740 35 1195 Heating current A A...

Page 31: ...d under the following conditions For cooling For heating Air inlet temperature C Indoor coil assembly Outdoor coil assembly Dry bulb Wet bulb Dry bulb Wet bulb 27 19 35 24 Air inlet temperature C Indoor coil assembly Outdoor coil assembly Dry bulb Wet bulb Dry bulb Wet bulb 20 7 6 ...

Page 32: ... manufacturer TOSHIBA CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...

Reviews: