High Wall, Heat Pump Type
Service Manual
26
Toshiba
5
SPECIFICATIONS OF ELECTRICAL PARTS
5-1. Indoor Unit
RAS-07PKVP-E, RAS-10PKVP-E, RAS-13PKVP-E, RAS-16PKVP-E, RAS-18PKVP-E
RAS-07PKVP-ND, RAS-10PKVP-ND, RAS-13PKVP-ND, RAS-16PKVP-ND, RAS-18PKVP-ND
5-2. Outdoor Unit
RAS-07PAVP-E, RAS-10PAVP-E, RAS-13PAVP-E, RAS-16PAVP-E, RAS-18PAVP-E
RAS-07PAVP-ND, RAS-10PAVP-ND, RAS-13PAVP-ND, RAS-16PAVP-ND, RAS-18PAVP-ND
No.
Parts name
Type
Specifications
1
Fan motor (for Indoor Unit)
E:ICF-340-30-4
ND:ICF-340-30-4A
DC280–340V, 30W
2
Room temp. sensor (TA-sensor)
( – )
10k
Ω
at 25°C
3
Heat exchanger temp. sensor (TC-sensor)
( – )
10k
Ω
at 25°C
4
Heat exchanger temp. sensor (TCj-sensor)
( – )
10k
Ω
at 25°C
5
Humidity sensor
C7-M3R-TC2
31k
Ω
60%RH
6
Louver motor (right, left, Horizontal)
MP24Z3N
Output (Rated) 1W, 16 poles, DC12V
7
Louver motor (Moving panel)
MP24Z4N
Output (Rated) 1W, 16 poles, DC12V
No.
Parts name
Model name
Rating
1
Reactor
CH-57
L = 10mH, 16A
2
Fan motor (for Outdoor Unit)
ICF-140-43-4R
DC140V, 43W
3
Suction temp. sensor (TS sensor)
(Inverter attached)
10k
Ω
(25°C)
4
Discharge temp. sensor (TD sensor)
(Inverter attached)
1,905k
Ω
(120°C)
5
Outside air temp. sensor (TO sensor)
(Inverter attached)
10k
Ω
(25°C)
6
Heat exchanger temp. sensor (TE sensor)
(Inverter attached)
10k
Ω
(25°C)
7
Terminal block (6P)
JXO-6B
20A, AC250V
8
Compressor
DA111A1FD-21F
3-phases 4 poses 750W
9
Coil for P.M.V.
C12A-80A
DC12V
10
Coil for 4-way valve (Cooling/heating switching)
VHV-01AZ535A1
DC12V
11
Coil for 4-way valve (Comp. cylinder switching)
VHV-01AZ535B1
DC12V
12
Cord heater assembly (-ND model only)
CSC-2
AC230V, 75W
13
Heater fuse assembly (-ND model only)
—
AC250V, 3.15A
+00A08-010_01EN_SVM_HighWallHeatPump.book Page 26 Wednesday, March 4, 2009 11:22 AM