High Wall, Heat Pump Type
Service Manual
58
Toshiba
9-2. Optional Parts, Accessories and Tools
9-2-1. Optional Installation Parts
9-2-2. Accessory and Installation Parts
Part Code
Parts name
Q’ty
[Y]
Refrigerant piping
1 ea.
Indoor unit name
Liquid side
(Outer diameter)
Gas side
(Outer diameter)
RAS-07PKVP-E, RAS-07PKVP-ND
RAS-10PKVP-E, RAS-10PKVP-ND
RAS-13PKVP-E, RAS-13PKVP-ND
6.35 mm
9.52 mm
RAS-16PKVP-E, RAS-16PKVP-ND
RAS-18PKVP-E, RAS-18PKVP-ND
6.35 mm
12.7 mm
[Z]
Shield pipe (for extension drain hose) (polyethylene foam, 8 mm thick)
1
Attachment bolt arrangement of outdoor unit
• Secure the outdoor unit with the attachment bolts and nuts if
the unit is likely to be exposed to a strong wind.
• Use dia. 8 mm or dia. 10 mm anchor bolts and nuts.
• If it is necessary to drain the defrost water, attach drain nipple
to the base plate of the outdoor unit before installing it.
Part No.
Part name (Q’ty)
Part No.
Part name (Q’ty)
Part No.
Part name (Q’ty)
[1]
[4]
[7]
[2]
[5]
[8]
[3]
[6]
Parts marked with asterisk (*) are packaged
with the outdoor unit.
Others
Name
This model is not equipped with an extension
drain hose.
• For the extension drain hose, use a
commercially available one.
Owner’s manual
Installation manual
Important information
and warning*
B/W strips
(Energy efficiency labels)
Suction side
Diffuser
Drain hole
Elongated drain
hole
600
[8]
108 125
54
30
86
320
30
290
[7]
Installation plate × 1
Remote controller holder × 1
Drain nipple* × 1
Wireless remote controller × 1
Mounting screw
Ø4 × 25L × 7
Water-proof rubber cap* × 2
Battery × 2
Remote controller holder
mounting screw
Ø3.1 × 16L × 2