10-7-4. Indoor Fan Motor Automatically Starts to Spin by Turning
on Power Supply
Cause
The IC is built in the indoor fan motor. Therefore the P.C. board is also mounted to inside of the motor.
If the P.C. board is soldered imperfectly or the IC is defective, the fan motor may automatically rotate by turning on
power supply.
Inspection procedure
1) Remove the front panel. (Remove 2 screws.)
2) Remove the cover of the fan motor lead wires.
3) Check DC voltage with CN301 connector while the fan motor is rotating.
NOTE
• Do not disconnect the connector while the fan motor is rotating.
• Use a thin test rod.
Indoor fan starts rotating when power supply is turned on.
(Check output DC voltage of fan motor on P.C. board.)
Measure voltage between [3] (GND : Black)
and [5] (V line : Yellow) of motor connector (CN301)
while indoor fan motor is rotating.
DC 1.0V or more
P.C. board is defective.
6 (Blue)
5 (Yellow)
4 (White)
3 (Black)
2 –
1 (Red)
Motor is defective.
Under DC 1.0V
CN301
Yellow
Black
P.C. board
DC
Replace P.C. board.
Replace motor.