– 7 –
FILE NO. SVM-04032
Note : 1
• Capacity is based on the following temperature conditions.
Note : 2
• Charge refrigerant according to the table below.
refrigerant
*2
Need to charge
Over 15m up to 20m (20g/m) Over 15m up to 25m (30g/m)
refrigerant
Temperature
Condition
JIS C9612-1994
*SSA386/1983
Cooling
Heating
Cooling
Indoor unit inlet air temperature
(DB)
27°C
20°C
29°C
(WB)
19°C
12°C
19°C
Outdoor unit inlet air temperature
(DB)
35°C
7°C
46°C
(WB)
24°C
6°C
24°C
RAS-18UFHP-E3 / RAS-18UAH-E3
RAS-24UFHP-E3 / RAS-24UAH-E3
RAS-18UFP-E3 / RAS-18UA-E3
RAS-24UFP-E3 / RAS-24UA-E3
RAS-18UFPX3 / RAS-18UAX3
RAS-24UFPX3 / RAS-24UAX3
Refrigerant
RAS-18UFP-AR3 / RAS-18UA-AR3
RAS-24UFP-AR3 / RAS-24UA-AR3
RAS-18UFPX3-T2 / RAS-18UAX3-T2
RAS-24UFPX3-T / RAS-24UAX3-T
*1 No need to charge
15m or less
15m or less