14
EN
This air conditioner is equipped with an Automatic restarting facility which allows the air conditioner to resume
the set operating conditions in the event of a supply power shutdown without the use of the remote control.
The operation will resume without warning three minutes after the power is restored.
To set the auto restart function, proceed as follows:
The power supply to the unit must be on the function will not set if the power is off.
To enable the auto restart function, push the TEMPORARY button continually for 3 seconds.
The air conditioner will acknowledge the setting and beep 3 times. The system will now restart automatically.
The above auto restart settings can be carried out:
(1) When the air conditioner is in stand-by (not running).
Push the TEMPORARY button for more than 3 seconds.
•
The air conditioner starts to operate.
The green lamp will be indicated.
•
About 3 seconds after, the air conditioner beeps 3 times.
The lamp will change from green to orange.
•
The air conditioner is operating.
If the air conditioner is not required to run at this time, push the
TEMPORARY button once more or use the remote control to stop the
air conditioner.
(2) When the air conditioner is in operation.
Push the TEMPORARY button for more than 3 seconds.
•
The air conditioner stops operating.
The green lamp goes off.
•
The air conditioner beeps 3 times 3 seconds later, after pushing the button.
•
The air conditioner stops.
If the air conditioner is not required to stop at this time, use the remote control to restart the air conditioner.
During the subsequent operation, the orange lamp is indicated.
•
The auto restart operation will not accept an instruction if timer operation with the remote control is selected.
•
The louver swing (AUTO) operation will not resume, after restarting the air conditioner by the AUTO
RESTART OPERATION.
To cancel the auto restart operation, proceed as follows:
Repeat the setting procedure: the air conditioner will acknowledge the instruction and beep three times.
The air conditioner will now require to be manually restarted with the remote control after the main supply is
turned off.
Cancellation is carried out:
(1) When the air conditioner is in stand-by (not running).
Push the TEMPORARY button for more than 3 seconds.
•
The air conditioner starts to operate.
The orange lamp will be indicated.
•
About 3 seconds after, the air conditioner beeps 3 times.
The lamp will change from orange to green.
•
The air conditioner is operating.
If the air conditioner is not required to run at this time, push the
TEMPORARY button once more or use remote control to stop the air
conditioner.
(2) When the air conditioner is in operation.
Push the TEMPORARY button for more than 3 seconds.
•
The air conditioner stops operating.
The orange lamp is turned off.
•
About 3 seconds after, the air conditioner beeps 3 times.
•
The air conditioner stops.
If the air conditioner is not required to stop at this time, use the remote control to restart the air conditioner.
During subsequent operation, the green lamp is indicated.
AUTO RESTART OPERATION
HOW TO SET THE AUTO RESTART
HOW TO CANCEL THE AUTO RESTART
The AUTO RESTART OPERATION is not set to work on shipment from the factory, and so it is necessary
to set it to function as required.
INFORMATION
PRE.D
FILTER
Hi POWER
TEMPORARY
button
PRE.D
FILTER
Hi POWER
TEMPORARY
button