TEMPORARY OPERATION
12
In case of the misplaced or discharged remote control
●
Pressing the RESET button, the unit can start
or stop without using the remote control.
●
Operation mode is set on AUTOMATIC
operation, preset temperature is 24°C and fan
operation is automatic speed.
AUTO RESTART OPERATION
13
To automatically restart the air conditioner after the power failure (Power of
the unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to
set the operation. (3 beep sound and OPERATION lamp blink 5 time/
sec for 5 seconds)
2. Press and hold the RESET button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
•
In case of ON timer or OFF timer are set, AUTO RESTART
OPERATION does not activate.
SELF CLEANING OPERATION
(COOL AND DRY OPERATION ONLY)
14
OPERATION AND PERFORMANCE
17
1. Three-minute protection feature: To prevent the unit from being
activated for 3 minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before the
heating operation starts.
3. Warm air control: When the room temperature reaches the set
temperature, the fan speed is automatically reduced and the outdoor
unit will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoors and released into
the room. When the outdoor temperature is too low, use another
recommended heating apparatus in combination with the air
conditioner.
6. Consideration for accumulated snow: Select the position for outdoor
unit where it will not be subjected to snow drifts, accumulation of
leaves or other seasonal debris.
7. Some minor cracking sound may occur when unit operating. This is
normal because the cracking sound may be caused by expansion/
contraction of plastic.
Note:
Item 2 to 6 for Heating model
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature Room Temperature
Heating
–15°C ~ 24°C
Less than 28°C
Cooling
–15°C ~ 46°C
21°C ~ 32°C
17°C ~ 32°C
–15°C ~ 46°C
Dry
The unit does not operate.
Cooling or Heating is abnormally low.
●
The power main switch is
turned off.
●
The circuit breaker is
activated to cut off the power
supply.
●
Stoppage of electric current
●
ON timer is set.
●
The filters are blocked with dust.
●
The temperature has been set
improperly.
●
The windows or doors are opened.
●
The air inlet or outlet of the outdoor
unit is blocked.
●
The fan speed is too low.
●
The operation mode is FAN or DRY.
●
POWER SELECTION function is
set 75% or 50% (
This function is
depend on remote controller
).
TROUBLESHOOTING (CHECK POINT)
18
REMOTE CONTROL A-B SELECTION
19
To separate using of remote control for each indoor unit in case of 2 air
conditioner are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the
pencil. “00” will be shown on the display. (Picture
a
)
4. Press
during pushing
. “B” will show on the display
and “00” will disappear and the air conditioner will turn OFF. The
Remote Control B is memorized. (Picture
b
)
Note:
1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not “A” display.
3. Default setting of Remote Control from factory is A.
Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control
●
Clean the indoor unit and the remote control with a wet cloth when
needed.
●
No benzine, thinner, polishing powder or chemically-treated duster.
Air filters
Clean every 2 weeks.
1. Open the air inlet grille.
2. Remove the air filters.
3. Vacuum or wash and then dry them.
4. Reinstall the air filters and close the air inlet grille.
MAINTENANCE
16
MANUAL DEFROST OPERATION
15
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during “Cool” or “Dry” mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
more 2 times
within 30 seconds.
ES
EN
SILENT
SILENT
DISPLAY LAMP BRIGHTNESS ADJUSTMENT
11
To decrease the display lamp brightness or turn it off.
1. Press and hold
for 3 seconds until brightness level (
,
,
or
) is shown on remote control LCD then release the button.
2. Press
Rise
or
Decrease
to adjust brightness in 4 levels.
Remote control
LCD
Brightness
Operation display
Lamp illuminates full brightness.
100%
Lamp illuminates 50% brightness.
50%
Lamp illuminates 50% brightness and the operation lamp
is turned off.
50%
All lamps are turned off.
All turned off
●
In the examples of and , the lamp illuminates for 5 seconds before
going off.
To defrosting the heat exchanger of the outdoor unit during Heating operation.
Press and hold
: for 5 sec. then remote control display will show
[ ] as picture
a
for 2 sec.