NOTE :
• The maximum pipe length of this air conditioner is 25 m. When the pipe length exceeds 15m, the additional
Max. : 2
5
m
Deoxidized copper pipe
NOTE :
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
INDOOR UNIT
T1
TO
Temp. measurement
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Allo
w
ab
le height
diff
erence :
10m
Allo
w
ab
le pipe length
P
Pressure measurement
Gauge attaching port
Vacuum pump connecting port
Pulse Modulating
valve at liquid side
Ø1.2 x 80
Ø1.2 x 80
TD
4-way valve
Compressor
DA150A1T-21F
TS
T2
Outdoor heat
exchanger
Split capillary
Temp. measurement
Propeller fan Refrigerant amount :
1.05
kg
OUTDOOR UNIT
Muffler
Muffler
TE
TC
TA
Min. :
2
m
Chargeless : 15m
Charge : 20g/m
(16 to 2
5
m)
charging of refrigerant, 20g per 1m for the part of pipe exceeded 15m is required. (Max. 200g)
Tcj
RAS-13G2KVP-E / RAS-13G2AVP-E
–
20
−
FILE NO. SVM-14017
RAS-16G2KVP-E / RAS-16G2AVP-E
Outer dia. : 9.52mm(13)
: 12.7mm(16)
Thickness : 0.8mm