Check the flare nut connections for the gas leak with
a gas leak detector or soap water.
Fig.
10
-
6
-1
Information
The product is shipped with Auto Restart function
in the ON position. Turn it OFF if this function is
not required.
<
How to turn OFF the Auto Restart Function
>
Press and hold the [OPERATION] button on the
indoor unit for 3 seconds (3 Beep sounds but
OPERATION lamp does not blink).
10-
6
. Others
10-
6
-1
. Gas leak test
Check places
for outdoor unit
Check places for
indoor unit (Flarenut
connection)
• When two indoor units are installed in the
same room or adjacent two rooms, if operating
a unit, two units may receive the remote
control signal simultaneously and operate. In
this case, the operation can be preserved by
setting either one remote control to B setting.
(Both are set to A setting in factory shipment.)
• The remote control signal is not received when
the settings of indoor unit and remote control
are different.
• There is no relation between A setting/B
setting and A room/B room when connecting
the piping and cables.
To separate using of remote control for each
indoor unit in case of 2 air conditioner are
installed near.
Remote Control B Setup.
1.
Press [RESET] button on the indoor unit to
turn
the air conditioner ON.
2.
Point the remote control at the indoor unit.
3.
Push and hold [CHECK] button on
back side of
Remote
Control
.
“00” will be
shown on the
display (Picture
1
).
10-
6
-2
. Remote Control A-B Selection
<
How to turn ON the Auto Restart Function
>
Press and hold the [OPERATION] button on the
indoor unit for 3 seconds (3 Beep sounds and
OPERATION lamp blink 5 time/sec for 5
seconds).
NOTE
•
In case of ON timer or OFF timer are set, AUTO
RESTART OPERATION does not activate.
•
Default setting of AUTO RESTART OPERATION
is ON.
1
4.
Press [MODE] during pushing [CHECK]. “B”
will show on the display and “00” will disappear
and the air conditioner will turn OFF.
The
Remote Control B is memorized (Picture
2
).
2
Note : 1. Repeat previous step to reset Remote
Control to be A.
2.
3.
Remote Control A have not “A” display.
Default setting of Remote Control from
factory is A.
10
-
6
-3. Test operation
To switch the TEST RUN (COOL) mode, press [RESET]
button for 10 sec. (The beeper will make a short beep.)
OPERATION /
RESET Button
Fig.
10
-
6
-
3
10
-
6
-4. Auto restart
function
setting
This product is designed so that, after a power failure,
it can restart automatically in the same operating mode
as before the power failure.
Fig.
10
-
6
-
2
•
•
- 82 -