Cross flow fan
<Caution at reassemblying>
1) To incorporate the Fan-motor incorporate
the Motor into the position in the following
figure, and then install the Fan-motor
- Install the cross flow fan so that the right
end of the 1st joint from the right of the
Cross flow fan is set keeping 5.0mm
from closed wall of the main unit.
- Holding the set screw, install the
cross flow fan so that flat area on shaft of
the fan motor comes to the mounting hole
of the set screw.
- Perform positioning of the fan motor as
follow:
- When assembling the fan motor, the fan
motor must be installed in such a way that
the fan motor leads will be taken out is
positioned at the bottom front.
- After assembling the two hooking claws of
the motor band(right) into the main body,
position the fan motor, insert it, and then
secure the motor band(right) using the two
fixing screws.
No.
Part name
Work procedure
Remarks
11
Fan motor D
shaft
Double point set
screw
5 mm.
FILE NO. SVM-17050