7-2. Operation Data
<Cooling>
Tempeature
Model name
Standard
Heat exchanger
Indoor
Outdoor
Compressor
condition(°C)
RAS-
pressure
pipe temp.
fan mode
fan mode
revolution
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
(rps)
27/19
35/-
25
PKVPG
-ND
1
4
to 1
6
39 to 41
High
High
27
35
PKVPG
-ND
1
2
to 1
4
41 to 43
High
High
37
<Heating>
Tempeature
Model name
Standard
Heat exchanger
Indoor
Outdoor
Compressor
condition(°C)
RAS-
pressure
pipe temp.
fan mode
fan mode
revolution
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
(rps)
20/-
7/6
25
PKVPG
-ND 2.
1
to 2.
3
33 to 35
3
to
4
High
High
3
6
35
PKVPG
-ND 2.
4
to 2.
6
36 to 38
2 to 3
High
High
42
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchaner path U bent.
(Thermistor themometer)
2. Connecting piping condition : 5 m
1.
1
to 1.2
0.9 to 1.1
FILE NO. SVM-17050