8. CONTROL BLOCK DIAGRAM
8-1. Indoor Unit
M.C.U.
Indoor Unit Control Unit
Power Supply
Serial Signal Communication
(Operation Command and Information)
Serial Signal Transmitter/Receiver
Micro Switch
Converter
(D.C circuit)
Noise Filter
Indoor
Air purifier
unit
Louver
Motor
Louver Motor
Drive Control
Indoor Fan
Motor Control
Initializing Circuit
Clock Frequency
Oscillator Circuit
Power Supply
Circuit
Heat Exchanger Sensor (TC)
Room Temperature Sensor (TA)
Infrared Rays Signal Receiver
and Indication
Functions
·
Cold draft preventing Function
·
3-minute Delay at Restart for Compressor
·
Fan Motor Starting Control
·
Processing
(Temperature Processing)
·
Timer / Weekly Timer
·
Serial Signal Communication
·
Clean Function
·
Power Selection
& Silent CDU
·
Fireplace & 8
°C
Indoor
Fan Motor
Heat Exchanger Sensor (TCJ)
Infrared Rays, 36.7kHz
Remote Controller
Thermo. Setting
Fan Speed Selection
ON TIMER Setting
OFF TIMER Setting
Louver AUTO Swing
Louver Direction Setting
Operation Mode Selection
AUTO, COOL, DRY, HEAT
REMOTE CONTROLLER
ECO
Hi-POWER
POWER-SEL & Silent CDU
WEEKLY ON / OFF
Operation ( )
COMFORT SLEEP
PURE
Air Flow
Fireplace & 8°C
FILE NO. SVM-17050
- 23 -