10-3-
6
.
Drainage
1. Run the drain hose sloped downwards.
NOTE :
• The hole should be made a slight downward slant
on the outdoor side.
Fig. 10-3-1
7
2. Put water in the drain pan and make sure that the
water is drained out of doors.
3. When connecting extension drain hose, insulate
the connecting part of extension drain hose with
shield pipe.
Fig. 10-3-1
8
CAUTION
Arrange the drain pipe for proper drainage from
the unit. Improper drainage can result in
dew-dropping.
This air conditioner has the structure designed
to drain water collected from dew, which forms
on the back of the indoor unit, to the drain pan.
Therefore, do not store the power cord and other
parts at a height above the drain guide.
50 mm
or more
Do not rise the drain hose.
Do not form the drain hose
into the wavy shape.
Do not put the
drain hose end
into water.
Do not put the drain
hose end in the
drainage ditch.
Shield pipe
Extension drain hose
Drain hose Inside the room
Fig.
10-3-
19
Wall
Drain
guide
Space for pipes
FILE NO. SVM-17050
- 71 -