10-4. Outdoor Unit
10-4-1. Installation Place
• A place which provides enough space around the
outdoor unit as shown in the diagram.
• A place which can bear the weight of the outdoor
unit and does not allow an increase in noise level
and vibration.
• A place where the operation noise and discharged
air do not disturb neighbors.
• A place which is not exposed to a strong wind.
• A place free of combustible gases.
• A place which does not block a passageway.
• When the outdoor unit is to be installed in an
elevated position, be sure to secure its feet.
• An allowable length & height, please refer from
1. SPECIFICATIONS.
•
A place where the drain water does not cause any
problems.
Precautions for adding refrigerant
• Use a scale having a precision with at least 10 g
per index line when adding the refrigerant.
Do not use a bathroom scale or similar instrument.
• Use liquid refrigerant when refilling the refrigerant.
Since the refrigerant is in liquid form, it can fill
quickly.
Therefore, perform the filling operation carefully
and insert the refrigerant gradually.
CAUTION
1. Install the outdoor unit without anything
blocking the discharging air.
2. When the outdoor unit is installed in a place
always exposed to strong winds like on the
coast or on a high story of a building, secure
the normal fan operation using a duct or a
wind shield.
3. Especially in windy areas, install the unit to
prevent the admission of wind.
4. Installation in the following places may result
in trouble.
Do not install the unit in such places.
• A place full of machine oil.
• A saline-place such as the coast.
• A place full of sulfide gas.
• A place where high-frequency waves are
likely to be generated, such as from audio
equipment, welders, and medical equip-
ment.
Fig. 10-4-2
10-4-2. Precautions about Installation in
Regions with Snowfall and Cold Temperatures
•
Do not use the supplied drain nipple for draining water.
•
Drain the water from all the drain holes directly.
hood and plate.
•
Do not use a double-stacked design.
•
To protect the outdoor unit from snow accumulation,
install a holding frame, and attach a snow protection
Snow protection plate
Snow protection hood
At least
50 cm
Snow accumulation line
Holding frame
Front
Anchor
bolts
Install at least 50 cm
above the snow
accumulation line.
Fig. 10-4-1
•
An allowable height level is up to 10 m.
Strong
wind