12-2. Outdoor unit
No.
Part name
Procedures
Remarks
1
Common procedure
1. Detachment
Wear gloves for this job.
Otherwise, you may injure your hands on
the parts, etc.
1)
Stop operation of the air conditioner, and
turn off the main switch of the breaker for air
conditioner.
2)
Remove the valve cover.
(ST
2
TØ4 × 10L 2 pcs.)
• After removing screw, remove the valve
cover pulling it downward.
3)
Remove cord clamp (ST2TØ4 × 14L 3 pcs.),
and then remove connecting cable.
4)
Remove the upper cabinet.
(ST
1
TØ4 × 10L 5 pcs.)
• After removing screws, remove the
upper
cabinet pulling it upward.
2. Attachment
1) Attach the water-proof cover.
NOTE
The water-proof cover must be attached
without fail in order to prevent rain water,
etc. from entering inside the indoor unit.
2)
Attach the upper cabinet.
(ST
1
TØ4 × 10L 5 pcs.)
3)
Perform cabling of connecting cable, and
attach the cord clamp.
• Fix the cord clamp by tightening the
screws (ST2TØ4 x 14L 3 pcs.), fitting 2
concave parts of the cord clamp to each
connecting cables.
4)
Attach the valve cover.
(ST
2
TØ4 x 10L 2 pcs.)
• Insert the upper part into the square hole
of the side cabinet, set hook claws of
the
valve cover to square holes (at three
positions) of the main unit, and attach it
pushing upward,
How to mount the water-proof cover
Upper cabinet
Waterproof cover
These 2 bending
parts shall be
put inside of a unit
by bending
these 2 ports.
This part shall be
put on
the side cabinet.
Fit the corner of
the water
proof cover to
the corner of
the front cabinet.
This line shall
be pavallel to
the front cabinet
This part shall cover the
gap between the inverter
box and the front cabinet.
Valve cove
NOTE
NOTE
- 115 -
FILE NO. SVM-17057