6-1. Indoor Unit
6-2. Outdoor Unit
6. SPECIFICATIONS OF ELECTRICAL PARTS
No.
Type name
Specifications
1 Compressor
KTN130D30UFZ
3-Phases (6-Poles) ;
1075
W
2 Fan Motor
WDF-340-A43-1
DC 140-340V ; 43W
3 Pulse Modulating Valve (PMV) coil
CAM-MD12TCTH-5
DC 12V
4
4-Way valve coil
STF-H01AJ1872A1
AC 220-240V
5 Reactor
CH-69-Z-T
L = 19mH, 10A
6 Suction temp. sensor
(TS sensor)
(Inverter attached)
10kΩ at 25°C
7 Discharge temp. sensor
(TD sensor)
(Inverter attached)
62kΩ at 20°C
8 Outside air temp. sensor
(TO sensor)
(Inverter attached)
9 Heat Exchanger temp. sensor
(TE sensor)
(Inverter attached)
10kΩ at 25°C
10 Terminal block
Parts name
10kΩ at 25°C
(6 poles)
JXO-6B
AC
600V, 30A
No.
Type
ype
Specificat
1
Fan Motor (for indoor)
RAS-
25PKVSG-ND
SJM-240-35
AC 220-240V, 35W
RAS-
35PKVSG-ND
ICF-340U30-2
DC340V, 30W
2
Room temp. sensor (TA-sensor)
(-)
10kΩ at 25°C
3
Heat exchanger temp. sensor (TC-sensor)
(-)
10kΩ at 25°C
4
Louver motor
24BYJ48A-080
Output (Rated) 4 phase, DC12V
Parts name
FILE NO. SVM-17057
- 20 -