Item
Operation flow and applicable data, etc.
Description
17. QUIET mode
Quiet mode is the system which, control the
revolving speed of indoor fan to work
constantly at lower than speed L. In addition,
noise level of indoor unit is less than usual.
Remarks :
When the "Quiet mode" selected from [FAN] button;
- The fan of the indoor unit will be restricted the
revolving speed at speed UL.
- The compressor speed is controlled as shown in
the figure.
1. Quiet mode is unable to work in dry mode.
2. Quiet mode is appropriate to work with less
cooling load and less heating load condition.
Because of the fan speed L- may cause not
enough the cooling capacity or heating
capacity.
18. Display lamp
brightness
adjustment
To decrease the display lamp brightness or turn it off.
Model
RAS-25PKVSG-ND RAS-35PKVSG-ND
13
13
Quiet Cool (Hz)
Cool/Heat min (Hz)
13
21
Quiet Heat (Hz)
21
29
When is cancel "Quiet mode". The [FAN] is selected
other speed.
19. FILTER
Indicator
When the elapsed time reaches 1000 hours after
air conditioner operation, the FILTER indicator lights.
After cleaning the filters, turn off the FILTER indicator.
How to Turn Off FILTER Indicator
Press [RESET] button on the indoor unit.
NOTE :
If [RESET] button is pushed while the FILTER indicator
is not lit, the indoor unit will start the automatic
operation.
LAMP BRIGHTNESS ADJUSTMENT
While operating (Auto, Cool, Heat or Dry), press and hold
5 seconds.
Press
Rise
or
Decrease
to adjust brightness which can be set at 4 levels or
to turn it off.
Rremote control LCD
Operation display
Brightness
Lamp illuminates an operation with full brightness.
100%
Lamp illuminates an operation with 50% brightness.
50%
Lamp illuminates an operation with 50% brightness and the
operation mode lamp is turned off.
50%
All lamps are turned off.
All turned off
l
In the examples of
and
, the lamp illuminates for 5 seconds before going off.
FILE NO. SVM-17057