Item
Operation flow and applicable data, etc.
Description
•
On demand defrost
In certain extreme condition, one can manually
defrost at any time by pressing button on the
remote controller.
<On demand defrost setting>
In AUTO or Heat mode, pass SET
button and hold for 5 seconds. When
this function activate, DF will be shown
on display.
20. Defrost control
(Only in heating
operation)
•
Strong defrost
Upgrade defrost ability when normal defrost ability
is not enough by increase defrosting finished
operation.
<Finish of defrost operation for strong
defrost>
•
Do cut the jumper J803 on CDU PCB
Returning conditions from defrost
operation to heating operation
1)Temperature of outdoor heat exchanger
rises to +13°C or higher.
2)Temperature of outdoor heat exchanger is
kept at +10°C or higher for 80 seconds.
3)Defrost operation continues for
20 minutes.
•
SET
WP-030
T101
C08
C07
IC81
J805
J804
J803
FILE NO. SVM-17057