Item
Operation flow and applicable data,etc
Description
23. Silent
Operation
Silent button on remote controller is pressed.
Silent 1:
Cooling/heating capacity is limited maximum
for 70% of rated. Only compressor speed is
limited.
Silent 2:
CDU sound level is limited for lowest CDU
sound level. Compressor and CDU fan speed
are limited.
This function is used when the user need
to keep silent at outdoor side. It is limit
maximum compressor speed and CDU
fan speed. Sound level can be
implemented by 2 silent level.
Sound level:
Rated level > Silent 1 > Silent 2
Note:
Due to Silent operation reason,
In adequate cooling/heating capacity may
occur.
Silent Operation description
Models
Silent
Cooling
Heating
Operation Compressor
CDU
Compressor
CDU
frequncy
Fan Speed
frequncy
Fan Speed
(rps)
(rpm)
(rps)
(rpm)
RAS-25PAV
S
G-ND Silent 1
Silent 2
RAS-35PAV
S
G-ND Silent 1
Silent 2
23
13
31
22
normal
600
normal
600
35
21
41
2
9
normal
600
normal
600
POWER-SELECTION AND SILENT OPERATION
[100%]
[75%]
[50%]
SILENT#2
SILENT#1
FILE NO. SVM-17057
- 45 -