10. INSTALLATION PROCEDURE
10-1. Installation Diagram of Indoor and Outdoor Units
Before installing the wireless remote controller
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (-) positions.
3 Batteries
2 Wireless remote controller
2
3
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
right
Rear
left
Bottom left
Left
Insulate the refrigerant pipes separately
with insulation, not together.
6 mm thick heat resisting
polyethylene foam
1
Batteries
6
Flat head
wood screw
4
Remote control
holder
Vinyl tape
Apply after carrying
out a drainage test.
Wireless remote control
Saddle
Extension drain hose
(Not available, provided
by installer)
Shield pipe
Air fi lter
Hook
Installation
plate
Hook
65 mm or more
300 mm or more
300 mm or more
600 mm
or more
100 mm or more
100 mm or more
600 mm or more
600 mm or more
For the rear left and left piping
Wall
Make sure to run the drain hose sloped
downward.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
The fl are connection should be installed
outdoors.
Refrigerant piping
must be protected from
physical damage.
Install a plastic cover or
equivalent.
FILE NO. SVM-17057