47
−
10. PRESET OPERATION
Set your preferred operation for future use. The setting will be memorized by the
Note:
· Keep the remote control in accessible transmission to the indoor unit;
otherwise, the time lag of up to 15 minutes will occur.
· The setting will be saved for the next same operation.
unit for future operation (except air flow direction).
1. Select your preferred operation.
2. Press and hold for 3 seconds to memorize the setting. The mark
P
displays.
3. Press : Operate the preset operation.
11. AUTO RESTART OPERATION
To automatically restart the conditioner after the power failure (Power of the unit
must be on.)
1. Press and hold the RESET button on the indoor unit for 3 seconds to set the
operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5 secpmds)
•
Do not operate ON timer and OFF timer.
2. Press and hold the RESET button on the indoor unit for 3 seconds to cancel the
Setting
operation. (3 beep sound but OPERATION lamp does not blink)
14. COMFORT SLEEP OPERATION
To save energy while sleeping, automatically control air flow and automatically turn OFF.
Press : Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note:
The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase). For heating operation,
the set temperature will decrease.
15. 8°C OPERATION
1. Press button to change to 8°C set temperature heating operation.
2. Press to adjust setting temperature from 5°C to 13°C.
FILE NO. SVM-11016
13
. POWER-SELECTION OPERATION
This function is used when its circuit breaker is shared with other electrical appliances.
Press : Select: (for 100%), (for 75%), (for 50%)
In case of 75% and 50% level, number "75" or "50" also flashes for 2 seconds.
It limits the maximum current/ power consumption to 100%, 75% or 50%.
The lower the percentage, the higher the saving and also the longer the compressor lifetime.
•
When the level is selected, PWR-SEL level flashes on LCD display for 3 seconds.
inadequate capacity may occur.
•
Due to the reason that POWER SELECT FUNCTION limits the maximum current,
Note:
8°C will operate in Heating mode only. If Air conditioner performs in cooling
operation (including automatic cooling) or dry operation it will change to
heating operation.
1
2
. QUIET OPERATION
To operate at super low fan speed for quiet operation (except in DRY mode)
Press
[Fan] Button
: Start and stop the operation.
Note:
Under certain conditions, QUIET operation may not provide adequate
cooling or heating due to low sound features.