10. INSTALLATION PROCEDURE
10-1. Installation Diagram of Indoor and Outdoor Units
FILE NO. SVM-11016
Insulate the refrigerant pipes separately
with insulation, not together.
2
3
8
6
4
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
For the rear left and left piping
Wall
Make sure to run the drain hose sloped
downward.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
right
Rear
left
Bottom left
Left
6 mm thick heat resisting
polyethylene foam
1
Batteries
Pan head
wood screw
Remote control holder
Vinyl tape
Apply after carrying
out a drainage test.
Wireless remote control
Saddle
Extension
drain hose
(Not available,
provided by installer)
Shield pipe
Plasma air purifier
(Att
ach
to t
he f
ron
t pa
nel.
)
Air filt
er
Hook
Installation
plate
Hook
6
5
m
m
o
r
m
o
re
170 m
m or m
ore
170 m
m or
more
6
0
0
m
m
o
r
m
o
re
100
mm
or m
ore
100
mm
or
mo
re
60
0 m
m
or
mo
re
600
mm
or m
ore
5
Filter
Before installing the wireless remote controller
•
Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (- ) positions.
3 Batteries
2 Wireless remote controller