7-
2
.
Operation Data
<Cooling>
NOTES :
Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
Model name
Standard
Indoor
Outdoor Compressor
pressure
fan mode
fan mode
revolution
Indoor Outdoor
P (MPa)
T1 (°C)
T2 (°C)
(rps)
27/19
35/-
25U2FVG-ND
1.
1
to 1.
2
1
2
to 1
3
37
to 4
0
High
High
35
condition(°C)
Tempeature
Heat exchanger
pipe temp.
Connecting
piping
(
m
)
35U2FVG-ND
0.9
to 1.1
9 to 10
41
to 4
2
High
High
44
5
Model name
Standard
Indoor
Outdoor Compressor
pressure
fan mode
fan mode
revolution
Indoor Outdoor
P (MPa)
T1 (°C)
T2 (°C)
(rps)
20
/
-
7/6
25U2FVG-ND
2.1
to
2.3
35
to
36
3
to 4
High
High
52
condition(°C)
Tempeature
Heat exchanger
pipe temp.
Connecting
piping
(
m
)
35U2FVG-ND
2.1
to
2.3
34
to
36
3
to 4
High
High
49
5
<
Heating
>