10-
5
-
3
. Remote Control A-B Selection
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly.
Remote Control B Setup.
1. Push and hold
button on the Remote Control by the tip of the pencil.
"00" will be shown on the display
2. Press
. "B" will show on the display and "00" will
during pushing
CHECK
disappear and the air conditioner will turn OFF. The Remote Control B
is memorized
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from factory is A.
Unit B setup.
Press and hold MODE button for more than 20 seconds.
When A setup changed to B setup : 5 beeps will sound and operation
lamp blinks for 5 seconds.
When B setup changed to A setup : 5 beep will sound.
10-
5
-
5
. Auto Restart Setting
This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power failure.
10-
5
-
4
. Test Operation
To switch the TEST RUN (COOL) mode, press OPERATION button for 10
seconds (The beeper will make a short beep).
Information
The product are shipped with Auto Restart function in the
ON
position. Turn it
OFF
as required.
(Picture
1
).
(Picture
2
).
How to cancel the Auto Restart
1. Press and hold the OPERATION button on
the indoor unit for 3 seconds to cancel the
operation
(3 “Pi” sounds but OPERATION lamp does
not blink).
2 Press and hold the OPERATION button
on the indoor unit for 3 seconds to set the
operation
(3 “Pi” sounds and OPERATION lamp blinks
5 times/sec for 5 seconds).
•
In case the ON timer or OFF timer is set,
Auto Restart operation does not activate.
- 82 -