Cooling / 240V >
Unit capacity
Total
(kW)
Cooling capacity
Power consumption
Operating current
A
B
C
Σ
kBTU
A
B
C
(kW)
(W)
(A)
1 unit
07
-
-
7
2.00
-
-
2.0
400
2.13
(
1.3
-
3.0
) (
240
-
840 ) (
1.30
-
3.75
)
10
-
-
10
2.70
-
-
2.7
640
3.10
(
1.3
-
3.2
) (
240
-
860 ) (
1.30
-
3.84
)
13
-
-
13
3.70
-
-
3.7
1050
4.66
(
1.4
-
4.2
) (
240
-
1400 ) (
1.30
-
6.15
)
16
-
-
16
4.50
-
-
4.5
1330
5.85
(
1.5
-
5.0
) (
250
-
1680 ) (
1.36
-
7.34
)
2 units
07
07
-
14
2.00
2.00
-
4.0
940
4.18
(
1.7
-
5.5
) (
270
-
1700 ) (
1.46
-
7.42
)
10
07
-
17
2.70
2.00
-
4.7
1260
5.55
(
1.7
-
5.8
) (
270
-
1830 ) (
1.46
-
7.98
)
13
07
-
20
3.38
1.82
-
5.2
1490
6.53
(
1.7
-
5.9
) (
270
-
1840 ) (
1.46
-
8.02
)
16
07
-
23
3.60
1.60
-
5.2
1390
6.11
(
1.7
-
6.2
) (
270
-
1870 ) (
1.46
-
8.14
)
10
10
-
20
2.60
2.60
-
5.2
1520
6.66
(
1.7
-
5.9
) (
270
-
1840 ) (
1.46
-
8.02
)
13
10
-
23
3.01
2.19
-
5.2
1480
6.49
(
1.7
-
6.0
) (
270
-
1850 ) (
1.46
-
8.06
)
16
10
-
26
3.25
1.95
-
5.2
1370
6.02
(
1.7
-
6.3
) (
270
-
1870 ) (
1.46
-
8.14
)
13
13
-
26
2.60
2.60
-
5.2
1430
6.28
(
1.7
-
6.1
) (
270
-
1850 ) (
1.46
-
8.06
)
16
13
-
29
2.85
2.35
-
5.2
1340
5.90
(
1.7
-
6.2
) (
270
-
1880 ) (
1.46
-
8.19
)
16
16
-
32
2.60
2.60
-
5.2
1300
5.73
(
1.7
-
6.4
) (
270
-
1900 ) (
1.46
-
8.27
)
・
The above specification values are those under the conditions that the indoor DB/WB=27/19
℃
and the outdoor DB/WB=35/–
℃
.
<
Heating / 220V >
Unit capacity
Total
(kW)
Heating capacity
Power consumption
Operating current
A
B
C
Σ
kBTU
A
B
C
(kW)
(W)
(A)
1 unit
07
-
-
7
2.70
-
-
2.7
620
3.34
(
1.0
-
4.9
) (
190
-
1640 ) (
1.13
-
7.82
)
10
-
-
10
4.00
-
-
4.0
1120
5.41
(
1.0
-
5.0
) (
190
-
1610 ) (
1.13
-
7.68
)
13
-
-
13
5.00
-
-
5.0
1540
7.36
(
1.0
-
5.5
) (
190
-
1830 ) (
1.13
-
8.70
)
16
-
-
16
5.50
-
-
5.5
1660
7.91
(
1.1
-
6.6
) (
210
-
2320 ) (
1.25
-
10.97 )
2 units
07
07
-
14
2.70
2.70
-
5.4
1370
6.57
(
1.3
-
7.2
) (
240
-
2240 ) (
1.42
-
10.60 )
10
07
-
17
3.22
2.38
-
5.6
1390
6.66
(
1.3
-
7.2
) (
250
-
2200 ) (
1.48
-
10.41 )
13
07
-
20
3.64
1.96
-
5.6
1340
6.43
(
1.3
-
7.5
) (
250
-
2250 ) (
1.48
-
10.65 )
16
07
-
23
3.88
1.72
-
5.6
1240
5.97
(
1.3
-
7.5
) (
240
-
2090 ) (
1.42
-
9.90
)
10
10
-
20
2.80
2.80
-
5.6
1350
6.48
(
1.3
-
7.3
) (
250
-
2160 ) (
1.48
-
10.23 )
13
10
-
23
3.24
2.36
-
5.6
1320
6.34
(
1.3
-
7.5
) (
250
-
2210 ) (
1.48
-
10.46 )
16
10
-
26
3.50
2.10
-
5.6
1220
5.87
(
1.3
-
7.5
) (
240
-
2070 ) (
1.42
-
9.81
)
13
13
-
26
2.80
2.80
-
5.6
1290
6.20
(
1.3
-
7.5
) (
250
-
2170 ) (
1.48
-
10.28 )
16
13
-
29
3.07
2.53
-
5.6
1190
5.73
(
1.3
-
7.5
) (
240
-
2020 ) (
1.42
-
9.58
)
16
16
-
32
2.80
2.80
-
5.6
1140
5.50
(
1.3
-
7.5
) (
240
-
1910 ) (
1.42
-
9.07
)
・
The above specification values are those under the conditions that the indoor DB/WB=20/-
℃
and the outdoor DB/WB=7/6
℃
.
Operating
status
Indoor unit
Operating
status
Indoor unit
FILE NO. SVM-15102
- 16 -