2. SPECIFICATIONS
CAUTION
• Exposure of unit to water or other moisture before installation may result in an electrical short.
Do not store in a wet basement or expose to rain or water.
• Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify
the noise level of the unit or where noise or discharged air might disturb neighbors.
• To avoid personal injury, be careful when handling parts with sharp edges.
• Perform the specified installation work to guard against an earthquake.
If the air conditioner is not installed appropriately, accidents may occur due to the falling unit.
RAS-3M18S3AV-E, -TR
For performance when each indoor unit is combined with other unit, refer to the separate table.
•
The specifications may be subject to change without notice for purpose of improvement.
•
Accessory Outdoor unit
Installation manual
1
Wiring connection
Power supply / interconnection
3 Wires : includes earth / 4 Wires : includes earth
Usable temperature range Outdoor (Cooling/Heating)
(
℃
)
-10 to 46
℃
/ -20 to 24
℃
Piping connection
Outdoor unit
A unit liquid side/gas side
φ
6.35 /
φ
12.7
B unit liquid side/gas side
φ
6.35 /
φ
9.52
C unit liquid side/gas side
Maximum chargeless length
(m)
50
Maximum height difference
(m)
10
φ
6.35 /
φ
9.52
Maximum length (per unit)
(m)
25
Maximum length (total)
(m)
50
(W)
1320
Type
Name of refirigerant
R410A
Weight of refigerant
(kg)
1.50
Air flow rate (Cooling/Heating)
(m³/h)
2177 / 2107
Type
Flare connection
Outdoor unit
Dimension
Height
(mm)
630
Width
(mm)
800
Depth
Twin rotary type with DC-inverter variable speed control
Model
DA136A1T-40N
Fan motor output
(W)
43
(mm)
300
Net weight
(kg)
46
Compressor
Motor output
COP
COP (Cooling/Heati
4.44 / 4.30
Operating noise
Outdoor
(Cooling/Heating)
Sound pressure level
(dBA)
47 / 50
Sound power level
(dBA)
60 / 63
Power supply
1Ph,220-240V,50Hz / 1Ph,220V,60Hz
Electric characteristics
Total
Operation mode
Cooling
Heating
Running current
Power factor
(%)
94
95
Starting current
(A)
5.64 / 5.39 / 5.17
(A)
5.64 / 5.39 / 5.17
7.54 / 7.22 / 6.92
Power consumption
(W)
1170
1580
Heating Capacity range
(kW)
1.9 to 8.0
Cooling Capacity
(kW)
5.2
Cooling Capacity range
(kW)
2.4 to 6.5
Unit model
Outdoor
RAS-
3M18S3AV-E, -TR
Connection indoor unit of this specification
RAS-
B16N3KV2-E1 + B10N3KV2-E1 ×2
Heating Capacity
(kW)
6.8
The indoor and outdoor units that can be used in combination are shown in the tables below.
NOTES
A 1-room connection is not an option for the indoor units (you cannot connect only one indoor unit).
Be sure to connect indoor unit in two or more.
2-1. Specifications
<Heat Pump Models>
Refer to page
18 to 19
Heat pump
Heat pump
Heat pump
RAS-2M14S3AV-E, -TR
RAS-2M18S3AV-E, -A, -TR
RAS-3M18S3AV-E, -TR
Table of models that can be used in combination
Refer to page
15 to 17
Refer to page
9 to 14
Type
Outdoor unit
Combinations of indoor unit models that can be connected
FILE NO. SVM-15102
- 5 -
Summary of Contents for RAS-2M14S3AV-E
Page 31: ...4 1 Outdoor Unit 4 CONSTRUCTION VIEWS FILE NO SVM 15102 31 Unit mm ...
Page 116: ......