FILE NO. SVM-18020
-2
- 48 -
Packed valve
(Gas side)
(dia.9,52)
P
Pr
me
e
a
s
s
s
ur
ur
e
e
ment
Gauge attaching port
connecting port
Packed valve
(Liquid side)
(dia.6,35)
Sectional shape
of heat insulator
Connecting pipe
Thickness : 0,8mm
dia.12,7
Connecting pipe
Thickness : 0,8mm
dia.9,52
Packed valve
(Gas side)
(dia.9,52)
Packed valve
(Gas side)
(dia.12,7)
Connecting pipe
Thickness : 0,8mm
dia.6,35
Packed valve
(Liquid side)
(dia.6,35)
Packed valve
(Liquid side)
(dia.6,35)
Outdoor unit
Refrigerant amount : 1,05kg (R32)
TE
TO
Propeller fan
T2
Temp.measurement
TGa
TGb
TGc
To
C room
To
B room
To
C room
To
B room
Pulse motor valve
at liquid side
(dia.1,
5
)
Al
lo
wa
bl
e
hei
g
ht
difference
:
1
0
m
A
llo
w
ab
le
pi
pe
l
en
gt
h
Cross flow fan
TA
Indoor unit A
T1
Temp. measurement
TC
Evaporator
・
RAS-3M18U2AVG-E,-TR
NOTE :
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
NOTE :
• You need not add refrigerant if the piping length is
50
m or less.
• Connection of only one indoor unit is unavailable. Two or more indoor units should be connected.
Per 1 unit
Max. : 25m
Min. : 2m
Total
Max. : 50m
TD
Compressor
DX136A1T-40N
High pressure
switch
TS