Outdoor Unit : RAS-3M18U2AVG-E, -TR
< Heating >
Temperature
No. of
Standard
Heat exchanger
Compressor
Condition
operating
pressure
pipe temperature
Indoor fan
revolution
Indoor
Outdoor
units
A
B
C
P (MPa)
T1 (
o
C)
T2 (
o
C)
(rps)
1 unit
05
-
-
2.2
to
2.4
39
to
41
3
to
5
High
33
07
-
-
2.2
to
2.4
39
to
41
3
to
5
High
37
10
-
-
2.9
to
3.1
48
to
50
2
to
4
High
55
13
-
-
3.3
to
3.5
52
to
54
1
to
3
High
67
16
-
-
3.2
to
3.4
51
to
53
1
to
3
High
73
2 Units
05
05
-
2.9
to
3.1
40
to
42
3
to
5
High
35
07
05
-
2.9
to
3.1
46
to
48
3
to
5
High
37
10
05
-
3.0
to
3.2
46
to
48
2
to
4
High
55
13
05
2.9
to
3.1
44
to
46
1
to
3
High
67
16
05
2.6
to
2.8
41
to
43
1
to
3
High
73
07
07
-
2.5
to
2.7
41
to
43
0
to
2
High
71
10
07
-
2.9
to
3.1
47
to
49
-1
to
1
High
90
13
07
2.8
to
3.0
45
to
47
-1
to
1
High
91
16
07
2.5
to
2.7
42
to
44
-1
to
1
High
91
10
10
2.8
to
3.0
46
to
48
-1
to
1
High
91
13
10
2.7
to
2.9
44
to
46
-1
to
1
High
91
16
10
2.4
to
2.6
41
to
43
-1
to
1
High
91
13
13
-
2.6
to
2.8
43
to
45
-1
to
1
High
91
27/19
35/-
16
13
2.3
to
2.5
39
to
41
-1
to
1
High
90
16
16
-
2.1
to
2.3
37
to
39
-1
to
1
High
90
3 Units
05
05
05
2.2
to
2.4
37
to
39
-1
to
1
High
93
07
05
05
2.3
to
2.5
36
to
38
-1
to
1
High
93
10
05
05
2.2
to
2.4
36
to
38
-1
to
1
High
93
13
05
05
2.1
to
2.3
36
to
38
-1
to
1
High
93
16
05
05
2.0
to
2.2
34
to
36
-1
to
1
High
93
07
07
07
2.1
to
2.3
36
to
38
-1
to
1
High
93
10
07
07
2.1
to
2.3
35
to
37
-1
to
1
High
93
13
07
07
2.0
to
2.2
35
to
37
-1
to
1
High
93
16
07
07
1.9
to
2.1
33
to
35
-1
to
1
High
93
10
10
07
2.0
to
2.2
35
to
37
-1
to
1
High
93
13
10
07
2.0
to
2.2
34
to
36
-1
to
1
High
93
16
10
07
1.9
to
2.1
33
to
35
-1
to
1
High
93
13
13
07
1.9
to
2.1
33
to
35
-1
to
1
High
93
16
13
07
1.9
to
2.1
32
to
34
-1
to
1
High
93
10
10
10
2.0
to
2.2
34
to
36
-1
to
1
High
93
13
10
10
2.0
to
2.2
34
to
36
-1
to
1
High
93
16
10
10
1.9
to
2.1
32
to
34
-1
to
1
High
93
13
13
10
1.9
to
2.1
33
to
35
-1
to
1
High
93
Indoor unit
NOTES
:
1.Measure surface temperature of heat exchanger pipe around of heat exchanger path U bent.(Thermistor thermometer)
2.Connecting piping condition : 5 meters × 2 units(5m/each indoor unit)
FILE NO. SVM-18020
-2
- 5
2
-