6. SPECIFICATIONS OF ELECTRICAL PARTS
Outdoor Unit
No. Parts name
Model name
Rating
1
Compressor
DX136A1T-40N
3-Phases (4-Poles);1100W
2
Outdoor fan motor
DX151A1T-30N
3
Reactor
CH-57-WL
10mH
、
16A
4
Reactor
CH-76-VK
9.9mH
、
1A
5
6
PMV coil
PQ-M10012-000313
DC12V
7
P.C. board(Main PCB)
MCC-1645
AC220-240V
8
P.C. board(Control PCB)
MCC-1665
DC 5V
9
P.C. board(Display PCB)
MCC-1646
DC 5V
10
Fuse (Mounted on P.C. board MCC-1645)
―
AC250V
、
25A
11
Fuse
―
AC250V
、
6.3A
12
Fuse (Mounted on P.C. board MCC-1645
、
MCC-1665)
―
AC250V
、
3.15A
13
Outdoor temp. sensor (TO sensor)
―
10kΩ (25
℃
)
14
15
Discharge temp. sensor (TD sensor)
―
50kΩ (25
℃
)
16
17
Temp. sensor at A room gas side (TGA-
sensor)
―
10kΩ (25
℃
)
18
Temp. sensor at B room gas side (TGB-
sensor)
―
10kΩ (25
℃
)
20
Temp. sensor at C room gas side (TGC-
sensor) *only 3M series
―
10kΩ (25
℃
)
Compressor thermo.
CS-12AL
ON:90
℃、
OFF:125
℃
Terminal block (3P)
*only 2M series
―
AC250V
、
20A
High-pressure SW
ACB-1UB177W
OFF:4.5MPa
19
Terminal block (6P)
―
AC600V
、
30A
ICF-340-A70-1
Output 70W
3-Phases (4-Poles);1100W
2M
21,3M41
series
3M
31
series
- 27 -