NOTE :
•
You need not add refrigerant if the piping length is
50
m or less.
•
Connection of only one indoor unit is unavailable. Two indoor units should be connected.
Packed valve
(Gas side)
(dia.9.52)
P
Preeasssu
m ur
re
ement
Gauge attaching port
connecting port
Packed valve
(Liquid side)
(dia.6.35)
Sectional shape
of heat insulator
Connecting pipe
Thickness : 0.8mm
dia.12.7
Connecting pipe
Thickness : 0.8mm
dia.9.52
Packed valve
(Gas side)
(dia.9.52)
Packed valve
(Gas side)
(dia.12.7)
Connecting pipe
Thickness : 0.8mm
dia.6.35
Packed valve
(Liquid side)
(dia.6.35)
Packed valve
(Liquid side)
(dia.6.35)
Outdoor unit
Refrigerant amount : 1.40kg (R32)
TO
Propeller fan
T2
Temp.measurement
TD
Compressor
D
X
151A1T-30N
High pressure
switch
Acc
umulator
tank
.
TGa
TGb
TGc
To
C room
To
B room
To
C room
To
B room
Pulse motor valve
at liquid side
(dia.1.6)
Allowable height difference : 1
0m
Allowable pipe length
Per 1 unit
Max. : 25m
Min. : 2m
Total
Max. : 50m
Cross flow fan
TA
Indoor unit A
T1
Temp. measurement
TC
Evaporator
NOTE :
Gas leak check position
Refrigerant flow (Cooling)
RAS-
3
M
3
1
U2ACVG-SG