9-
3
-5. How to set the SERVICE SWITCH SETTING.
If you want to set the
"POWER SAVE SETTING OFF ⇒ ON (8.5A) " .
○:ON, ●:OFF, ◎:Rapid Flashing(5 times/sec), ◇:Slow Flashing(1 time/sec)
D800
D801
D802
D803
D804
D805
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Green)
●
●
●
●
●
○
Push SW01
Hold time
D800
D801
D802
D803
D804
D805
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Green)
●
●
●
◎
●
●
Service support function display starts
t≥5 sec ?
Yes
Service switch setting display starts
No
D800
D801
D802
D803
D804
D805
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Green)
○
●
●
●
●
Initial status
Push SW01 & 02
at the same time
for 5 sec or more
Turn on the circuit breaker
Push SW02
1 time
Hold time
t≥5 sec ?
Push SW02
Yes
No
Function item
"Power save setting"
Setting "OFF" (No limit)
(Factory setting)
Setting "ON" (Limit)
Setting completion
(Limit)
Refer to 9-3-6.
Push SW01
8 times
D800
D801
D802
D803
D804
D805
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Green)
○
●
○
●
●
◎
D800
D801
D802
D803
D804
D805
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Green)
○
●
○
●
◎
◎
D800
D801
D802
D803
D804
D805
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Green)
●
○
○
●
○
◇
Push SW01
2 times
D800
D801
D802
D803
D804
D805
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Green)
○
●
○
○
○
●
Function item
"Current limit setting"
Setting "OFF" (11A)
(Factory setting)
Push SW02
1 time
Hold time
t≥5 sec ?
Push SW02
Yes
No
Setting "ON" (8.5A)
D800
D801
D802
D803
D804
D805
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Green)
○
○
○
○
○
◎
Setting completion
(8.5A)
D800
D801
D802
D803
D804
D805
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Yellow)
(Green)
○
○
○
○
○
○
●
●
●
●
◇
○
●
◎
◎
●
○
◇
○