– 3 –
FILE NO. SVM-06017
RAS-
30NKP2B-1
RAS-
30N2A2B
ITEM
Cooling
Capacity
220V
kW
7.00
Phase 1
∅
Power source V 220
V
Hz
60
Power consumption kW
3800
Power factor %
96
Running Indoor A
0.
4
current Outdoor A
17.60
Starting current A
81
Moisture removal
Liter/hr
Noise Indoor (H/M
+
/
M/
L
+/L
) dB
52/50
/
47/45/42
Outdoor (220)
dB 5
8
Refrigerant
Name of r
efrigerant
R-22
Rated amount kg 1.
90
Refrigerant control
Capillary tube
Gas side size mm
∅
15.88
Connection type
Flare connection
Liquid side size mm
∅
6.35
Interconnection Connection type
Flare connection
pipe
Maximum length
m
15*
1
(One way)
25
*2
Maximum height
m
1
0
difference
INDOOR UNIT
RAS-
30NKP2B-1
Height
mm
298
Dimensions Width
mm
998
Depth mm 2
20
Net weight
kg
12
Evaporator type
Finned tube
Indoor fan type
Cross flow fan
High fan m
3
/
h
1200
Air volume Medium fan m
3
/
h
1050
Low fan m
3
/h
9
00
Fan motor output W
3
0
Air filter
Honeycomb woven filter with PP frame
OUTDOOR UNIT
RAS-
30N2A2B
Height
mm
690
Dimensions Width
mm
880
Depth
mm
310
Net weight kg
69
Condenser type
Finned tube
Outdoor fan type
Propeller fan
Airflow volume
m
3
/
h
3558
Fan motor output
W
70
Compressor
Model
NHJ47NAHT
Output W 2
20
0
Safety device
IOL
Louver type
Automatic louver
Usable outdoor temperature range
°
C
21
~ 52
1. SPECIFICATIONS
MODEL
1
5
2.
1
Note *1 Chargeless pipe
*2 Maximum pipe