– 54 –
10-2. Outdoor Unit
1) Stop the operation of the air conditioner and turn off
its main power supply or remove the power supply
cord.
2) Remove the electrical parts cover.
(4 screws
∅
4 x 10L)
3) Remove 2 cord clamps (4 screws
∅
4 x 22L) and
disconnect the power supply cord and connecting
cable after removing 6 screwson on the terminal
block and 1 ground screw on the electrical parts
base.
4) Remove the top cabinet. (7 screws
∅
4 x 10L)
5) Remove the front cabinet. (2 screws
∅
4 x 10L)
6) Remove the side cabinet
(4 screws
∅
4 x 10L & 2 screws
∅
4 x 14L)
No.
Part name
Procedures
Remarks
Front cabinet
Side cabinet
Top cabinet
Electrical
parts cover
4 screws
∅
4 x 22L
1
Common
procedure
1) Perform the common procedure
1
2) Remove the capacitor band. (1 screw
∅
4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure
1
2) Remove the fixing screw. (1 screw
∅
4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure
1
2) Remove the fixing screw. (2 screws
∅
4 x 10L)
3) Disconnect the lead wires from the terminal.
1) Perform the common procedure
1
2) Remove the fixing screw. (1 screw
∅
4 x 10L)
3) Disconnect the lead wires from the terminal.
2
Running
capacitor
for compressor
4
Running
capacitor
for fan motor
5
Magnetic
contactor
Spark killer
(Cooling only model)
3
FILE NO. SVM-06017
Spark killer
Running capacitor
for compressor
Running capacitor
for fan motor
Magnetic contactor