– 105 –
CN601~
CN608
CN301 CN300
CN701
CN703
CN702
P.C. board base
P.C. board
No.
4
Part name
Control
board
assembly
Procedure
1. Disconnect lead wires and connectors connected
from the control board assembly to other parts.
1) Lead wires
• Connection with terminal block :
6 wires (Red, Orange, Pink, Black and two White wires)
• Connection with compressor : Remove the connector from CN09, 10, 11 (3P, White).
• Connection with reactor :
Remove the connector from P08, 09 (2P, White) and P12, P13 (2P, Gray).
*1 • Connection with 4-way valve : Remove the connector (3P).
• Connection with case thermo. : Remove the connector (2P).
2) Connectors
• Sub-control board assembly side
CN300 : Outdoor fan (3P, White)
CN301 : Outdoor fan position detection (5P, White)
CN601 : TO sensor (2P, White)
CN602 : TD sensor (3P, White)
*1 CN603 : TS sensor (2P, Black)
*1 CN604 : TE sensor (2P, White)
CN605 : TGa sensor (3P, Yellow)
CN606 : TGb sensor (3P, White)
CN607 : TGc sensor (3P, Green)
CN701 : A room pulse motor valve (6P, Yellow)
CN702 : B room pulse motor valve (6P, White)
CN703 : C room pulse motor valve (6P, Red)
*1 Heat pump model only.
2. Disconnect cable connecting the main control board
assembly side and sub-control board assembly.
• Main control board assembly side
CN04 : Connecting cable (3P, White)
CN05 : Connecting cable (2P, White)
CN06 : Connecting cable (5P, Red)
CN13 : Connecting cable (5P, Red)
• Sub-control board assembly side
CN302 : Connecting cable (3P, White)
CN303 : Connecting cable (2P, White)
CN800 : Connecting cable (5P, Red)
CN501 : Connecting cable (3P, Red)
3. The connecting cable connecting compressor and
P.C. board base and that connecting reactor and
P.C. board base are fixed to the inverter box with
bundling band. Cut off bundling band.
4. The connecting cables of the main P.C. board
base and the sub-P.C. board base are fixed with
bundling band. Cut off bundling band.
5. Remove the control board assembly from P.C.
board base.
1) Main control board assembly side
• Remove two claws of P.C. board base, and
remove upward the heat sink by hands.
• Remove three screws fixing the heat sink and
main control board assembly side.
• Remove red, orange, brown, and black connect-
ing cables connected to the diode block.
• Replace the P.C. board with a new one.
2) Sub-control board assembly side
• Remove P.C. board base from the inverter box.
• Remove three claws of P.C. board base, and
replace the board with a new one.
Remarks
CN300, CN302, CN303, CN501,
CN606, CN701, CN702, CN703,
case thermo. connector at the
sub-control board assembly side
are connectors with locks.
Therefore, remove the connector
while pushing the part indicated
by an arrow.
When mounting a new board,
check that the board is correctly
set in the groove of base holder
of P.C. board base.
Summary of Contents for RAS-3M18SACV-E
Page 21: ... 21 4 2 Outdoor Unit RAS 3M18SAV E RAS 3M18SACV E ...
Page 110: ... 110 MCC 1438 ...
Page 111: ... 111 MCC 818 ...