– 21 –
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
RAS-M10GKCVP-E, RAS-M13GKCVP-E, RAS-M16GKCVP-E
6-2. Outdoor Unit
RAS-3M23GACV-E
No.
1
2
3
4
Parts name
Fan motor (for indoor)
Room temp. sensor (TA-sensor)
Heat exchanger temp. sensor (TC-sensor)
Louver motor
Type
MF-280-30-5R
( – )
( – )
MP24Z
Specifications
DC280–340V, 30W
10k
Ω
at 25°C
10k
Ω
at 25°C
Output (Rated) 1W, 16 poles, DC12V
Parts name
SC coil (Noise filter) (L01)
SC coil (Noise filter) (L02)
DC-DC transformer
Fan motor (For outdoor)
Relay (Power relay)
Discharge temp. sensor
(TD-sensor)
Outside air temp. sensor
(TO-sensor)
Temp. sensor at A room
gas side (TGa-sensor)
Temp. sensor at B room
gas side (TGb-sensor)
Temp. sensor at C room
gas side (TGc-sensor)
Terminal block (6P)
Terminal block (2P)
Fuse
Electrolytic capacitor
Transistor module
Compressor
Compressor thermo.
Diode block (Rectifire)
Reactor (Main)
Reactor (Sub)
Model name
ADR25H200RBTB
SC-20-S03J
SWT-75
ICF-140-43-2R
G4A-1A-PE
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
—
—
For protection of switching power source (F04)
For protection of power factor converter circuit breakage
For protection of inverter input overcurrent
For protection of switching power source (F300)
For protection of power source
LLQ2G761KHUATF
6MBI40SS-060-51A
DA130A1F-25F
US622KXTMQO
D25XB60
CH-47-Z-T
CH-43-Z-T
Rating
AC 250V, 20A, 0.88mH
AC 250V, 20A, 0.3mH
Primary side DC 240 – 280V
Secondary side: 7V × 1, 13V × 1
16V × 3
DC 140V, 43W
Coil: DC 12V,
Contact: 20A, AC250V
64k
Ω
(20°C)
10k
Ω
(25°C)
10k
Ω
(25°C)
10k
Ω
(25°C)
10k
Ω
(25°C)
AC 250V, 20A
AC 250V, 20A
AC 250V, 3.15A
AC 250V, 25A
AC 250V, 25A
AC 250V, 3.15A
AC 250V, 6.3A
DC 400V, 760µF
600V, 40A
3 phases, 4 poles, 1,100W
OFF: 125 ± 4°C, ON: 90 ± 5°C
AC 800V, 30A
L = 8mH, 16A
L = 10mH, 1A
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Summary of Contents for RAS-3M23GACV-E