– 33 –
Item
5. Current release
control
Operation flow and applicable data, etc.
This function prevents troubles on the electronic parts of
the compressor driving inverter.
This function also controls drive circuit of the compressor
speed so that electric power of the compressor drive circuit
does not exceed the specified value.
Description
1) The input current of the outdoor
unit is detected in the inverter
section of the outdoor unit.
2) According to the detected
outdoor temperature, the
specified value of the current is
selected.
3) Whether the current value
exceeds the specified value or
not is judged.
4) If the current value exceeds the
specified value, this function
reduces the compressor speed
and controls speed up to the
closest one commanded from the
indoor unit within the range
which does not exceed the
specified value.
Outdoor temp. To
Setup of current release point
Capacity control continues.
Outdoor temp.
40˚C
10.1A
8.0A
16˚C
39˚C
11˚C
15.5˚C
10.5˚C
Cooling current release value
Current decrease
Outdoor unit inverter main
circuit control current
High
Low
Reduce compressor speed
Operating current
£
Setup value
6. Release protec-
tive control by
temperature of
indoor heat
exchanger
<In cooling/dry operation>
(Prevent-freezing control for indoor heat exchanger)
In cooling/dry operation, the sensor of indoor heat ex-
changer detects evaporation temperature and controls the
compressor speed so that temperature of the heat ex-
changer does not exceed the specified value.
7˚C
6˚C
5˚C
R
Q
P
Usual cooling capacity control
Reduction of compressor speed
Indoor heat e
xchanger temper
ature
When the value is
in Q zone, the
compressor speed
is kept.
1) When temperature of the indoor
heat exchanger drops below 5°C,
the compressor speed is
reduced. (P zone)
2) When temperature of the indoor
heat exchanger rises in the
range from 6°C to under 7°C, the
compressor speed is kept.
(Q zone)
3) When temperature of the indoor
heat exchanger rises to 7°C or
higher, the capacity control
operation returns to the usual
control in cooling operation.
(R zone)