78
–
No.
Part name
Pulse
modulating
valve coil
Fan guard
Remarks
Procedure
1. Detachment
1) Perform work of item 1 of
, and
,
,
.
2) Turn the coil clockwise or counterclockwise by
90 degrees, and remove coil from the pulse
modulating valve.
2. Attachment
1) Set take-out part of the lead wire of coil to the
coil inserting position of the pulse modulating
valve, and attach the coil.
2) Turn the coil clockwise or counterclockwise by
90 degrees, set surely the concave part at lower
part of the coil to the positioning hole of the
pulse modulating valve, and then fix the coil.
The pulse modulating valve has A, B and
C room side.
After mounting it, check that coil at B
room side (Red marking is marked on the
pulse modulating valve.) is connected to
CN13.
Check that coil at C room side (Green
marking is marked on the pulse modulat-
ing valve.) is connected to CN12 of the
control board assembly respectively.
1. Detachment
1) Perform work of item 1 of
, and
.
2) Remove the front cabinet, and put it down so
that fan guard side directs downward.
Perform work on a corrugated cardboard,
cloth, etc. to prevent flaw to the product.
3) Remove the hooking claws by pushing minus
screwdriver according to the arrow mark in the
right figure, and remove the fan guard.
2. Attachment
1) Insert claw of the fan guard in the hole of the
front cabinet. Push the hooking claws (10
positions) by hands and fix the claws.
All the attaching works have completed.
Check that all the hooking claws are fixed
to the specified positions.
Hooking claw
Minus screwdriver
Take-out part
of lead wire
Notch
Coil inserting
position
Coil inserting
position
Coil fix
position
Positioning
hole