– 9 –
Outdoor Unit : RAS-4M27GAV-E
<Cooling/230V>
• The above specification values are those under the conditions that the indoor DB/WB=27/19°C and the outdoor
DB/WB=35/–°C.
Indoor unit
Unit capacity (kW)
Power
supply
(V)
Operating
status
A
B
C
D
A
B
C
D
Cooling
capacity
(kW)
Power
consumption
(W)
Operating
current
(A)
Outdoor
noise
(dB)
230
1 unit
10
–
–
–
2.7
–
–
–
2.7
(1.4 to 3.2)
750
(640 to 950)
3.71
(3.52 to 4.44)
48
13
–
–
–
3.7
–
–
–
3.7
(1.4 to 4.4)
1200
(640 to 1520)
5.49
(3.52 to 6.88)
48
16
–
–
–
4.5
–
–
–
4.5
(1.4 to 5.0)
1650
(640 to 2000)
7.47
(3.52 to 8.87)
48
2 units
10
10
–
–
2.70
2.70
–
–
5.4
(2.5 to 6.3)
1530
(640 to 2040)
6.79
(3.48 to 9.05)
48
13
10
–
–
3.41
2.49
–
–
5.9
(2.7 to 6.6)
1810
(660 to 2220)
8.03
(3.59 to 9.85)
48
16
10
–
–
3.94
2.36
–
–
6.3
(2.9 to 6.9)
2040
(670 to 2400)
9.05
(3.64 to 10.65)
48
13
13
–
–
3.15
3.15
–
–
6.3
(2.9 to 6.9)
2040
(670 to 2400)
9.05
(3.64 to 10.65)
48
16
13
–
–
3.73
3.07
–
–
6.8
(3.0 to 7.2)
2320
(690 to 2570)
10.29
(3.75 to 11.40)
48
16
16
–
–
3.60
3.60
–
–
7.2
(3.2 to 7.5)
2550
(700 to 2750)
11.31
(3.80 to 12.20)
48
3 units
10
10
10
–
2.53
2.53
2.53
–
7.6
(3.8 to 8.2)
2400
(950 to 2720)
10.65
(4.59 to 12.07)
48
13
10
10
–
3.13
2.28
2.28
–
7.7
(3.9 to 8.3)
2410
(960 to 2740)
10.69
(4.64 to 12.16)
48
16
10
10
–
3.50
2.10
2.10
–
7.7
(4.0 to 8.5)
2410
(960 to 2790)
10.69
(4.64 to 12.38)
48
13
13
10
–
2.82
2.82
2.06
–
7.7
(4.0 to 8.5)
2410
(960 to 2790)
10.69
(4.64 to 12.38)
48
16
13
10
–
3.22
2.65
1.93
–
7.8
(4.1 to 8.6)
2430
(970 to 2810)
10.78
(4.69 to 12.47)
48
13
13
13
–
2.60
2.60
2.60
–
7.8
(4.1 to 8.6)
2430
(970 to 2810)
10.78
(4.69 to 12.47)
48
16
16
10
–
3.04
3.04
1.82
–
7.9
(4.1 to 8.7)
2440
(970 to 2830)
10.83
(4.69 to 12.56)
48
16
13
13
–
2.99
2.46
2.46
–
7.9
(4.1 to 8.7)
2440
(970 to 2830)
10.83
(4.69 to 12.56)
48
16
16
13
–
2.80
2.80
2.30
–
7.9
(4.2 to 8.9)
2440
(970 to 2880)
10.83
(4.69 to 12.78)
48
16
16
16
–
2.67
2.67
2.67
–
8.0
(4.3 to 9.0)
2450
(980 to 2900)
10.87
(4.73 to 12.87)
48
4 units
10
10
10
10
1.98
1.98
1.98
1.98
7.9
(4.0 to 8.7)
2450
(930 to 2800)
10.87
(4.49 to 12.42)
48
13
10
10
10
2.48
1.81
1.81
1.81
7.9
(4.1 to 8.8)
2450
(940 to 2820)
10.87
(4.54 to 12.51)
48
16
10
10
10
2.86
1.71
1.71
1.71
8.0
(4.1 to 9.0)
2500
(940 to 2860)
11.09
(4.54 to 12.69)
48
13
13
10
10
2.31
2.31
1.69
1.69
8.0
(4.1 to 9.0)
2500
(940 to 2860)
11.09
(4.54 to 12.69)
48
16
13
10
10
2.65
2.18
1.59
1.59
8.0
(4.2 to 9.1)
2500
(950 to 2880)
11.09
(4.59 to 12.78)
48
13
13
13
10
2.14
2.14
2.14
1.57
8.0
(4.2 to 9.1)
2500
(950 to 2880)
11.09
(4.59 to 12.78)
48
16
13
13
10
2.47
2.03
2.03
1.48
8.0
(4.2 to 9.2)
2500
(950 to 2900)
11.09
(4.59 to 12.87)
48
13
13
13
13
2.00
2.00
2.00
2.00
8.0
(4.2 to 9.2)
2500
(950 to 2900)
11.09
(4.59 to 12.87)
48
16
16
10
10
2.50
2.50
1.50
1.50
8.0
(4.2 to 9.2)
2500
(950 to 2900)
11.09
(4.59 to 12.87)
48
Summary of Contents for RAS-3M26GAV-E
Page 121: ... 121 MCC 1438 ...
Page 122: ... 122 MCC 818 ...