12-
1
.
Outdoor Unit
No.
1
Part name
Common
procedure
Procedure
CAUTION
Never forget to put on the gloves at working time;
otherwise an injury will be caused by the parts etc.
1.
Detachment
1)
Stop operation of the air conditioner, and turn
off the switch of the breaker.
2)
Remove the front panel.
(Hexagonal screw Ø4 × 10, 5 pcs.)
• After taking off screws, draw the front panel
2
to this side and remove it while pulling the
front panel downward
1
.
3)
Remove the power supply cable and the
indoor/outdoor connecting wire from the cord
clamp and the terminal.
4)
Remove the upper cabinet.
(Hexagonal screw Ø4 × 10, 4 pcs.)
2.
Attachment
1)
Connect the power supply cable and the
indoor/outdoor connecting wire to the terminal
and then fix them with the cord clamp.
2)
Mount the front panel.
(Hexagonal screw Ø4 × 10, 5 pcs.)
Remarks
12.
HOW TO REPLACE THE MAIN PARTS
Front panel
Front panel
Upper cabinet
(1) Downward
(2) This side
FILE NO. SVM-18051
- 86 -