– 19 –
Outdoor Unit : RAS-3M26YAV-E
<Heating/240V>
• The above specification values are those under the conditions that the indoor DB/WB=27/19°C and the outdoor DB/
WB=35/–°C.
• Indoor unit 10 : RAS-M10YKV-E, 13 : RAS-M13YKV-E, 16 : RAS-M16YKV-E
Indoor unit
Unit capacity (kW)
Power
supply
(V)
Operating
status
A
B
C
A
B
C
Heating
capacity
(kW)
Power
consumption
(W)
Operating
current
(A)
Outdoor
noise
(dB)
240
1 unit
10
–
–
4.0
–
–
4.0
(0.8 to 5.2)
1500
(300 to 1980)
6.38
(1.71 to 8.42)
48
13
–
–
5.0
–
–
5.0
(0.8 to 6.5)
2050
(310 to 2750)
8.72
(1.77 to 11.69)
48
16
–
–
5.5
–
–
5.5
(0.8 to 6.9)
2400
(310 to 3000)
10.20
(1.77 to 12.76)
48
2 units
10
10
–
3.60
3.60
–
7.2
(1.5 to 10.0)
2050
(320 to 3200)
8.72
(1.78 to 13.61)
48
13
10
–
4.22
3.38
–
7.6
(1.5 to 10.1)
2240
(320 to 3210)
9.52
(1.78 to 13.65)
48
16
10
–
4.57
3.33
–
7.9
(1.5 to 10.1)
2380
(320 to 3230)
10.12
(1.78 to 13.73)
48
13
13
–
3.95
3.95
–
7.9
(1.5 to 10.1)
2380
(320 to 3230)
10.12
(1.78 to 13.73)
48
16
13
–
4.35
3.95
–
8.3
(1.5 to 10.2)
2560
(320 to 3240)
10.88
(1.78 to 13.78)
48
16
16
–
4.30
4.30
–
8.6
(1.5 to 10.2)
2700
(320 to 3250)
11.48
(1.78 to 13.82)
48
3 units
10
10
10
2.87
2.87
2.87
8.6
(2.0 to 10.4)
2300
(380 to 2750)
9.78
(1.98 to 11.69)
48
13
10
10
3.35
2.68
2.68
8.7
(2.0 to 10.5)
2360
(380 to 2760)
10.03
(1.98 to 11.73)
48
16
10
10
3.59
2.61
2.61
8.8
(2.0 to 10.6)
2430
(380 to 2780)
10.33
(1.98 to 11.82)
48
13
13
10
3.14
3.14
2.51
8.8
(2.0 to 10.6)
2430
(380 to 2780)
10.33
(1.98 to 11.82)
48
16
13
10
3.34
3.03
2.43
8.8
(2.0 to 10.6)
2430
(380 to 2780)
10.33
(1.98 to 11.82)
48
13
13
13
2.93
2.93
2.93
8.8
(2.0 to 10.6)
2430
(380 to 2780)
10.33
(1.98 to 11.82)
48
16
16
10
3.26
3.26
2.37
8.9
(2.0 to 10.7)
2490
(380 to 2790)
10.59
(1.98 to 11.86)
48
16
13
13
3.16
2.87
2.87
8.9
(2.0 to 10.7)
2490
(380 to 2790)
10.59
(1.98 to 11.86)
48
16
16
13
3.09
3.09
2.81
9.0
(2.0 to 10.8)
2550
(380 to 2800)
10.84
(1.98 to 11.90)
48